Microsoft Windows 2003 [x86]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
275 Dell PowerEdge 1950 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
SP2
PCI
Express Emulex LP982−E2, 6, 15, 27, 28, 38 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
276 IBM xSeries: x3850M2 (7141)70, x3950M2
(7141)70 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
SP2
PCI
Express Emulex LPe11000−E2, 5, 6, 15, 35, 45;
IBM: 42C2069 (LPe11000)2, 4, 5, 6, 15, 35,
42C2071 (LPe11002)2, 5, 6, 15, 35, 45,
42D0485 (LPe12000)5, 6, 15, 35, 36, 63,
42D0494 (LPe12002)5, 6, 15, 35, 36, 62
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See31
277 Dell PowerEdge: R805, R900, R905 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
SP2
PCI
Express Emulex LPe11002−E2, 5, 6, 15, 35, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30, 31
278 Dell PowerEdge: 1800, 1850, 1950, 1950 III,
2800, 2850, 2900 III, 2950 III, 2970, 6800, 6850,
R805, R900, R905
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
SP2
PCI
Express Emulex LPe1150−E2, 5, 6, 15, 28, 35, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
279 Dell PowerEdge: R805, R900, R905 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
SP2
PCI
Express Emulex LPe1150−E2, 5, 6, 15, 35, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
280 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850,
6800, 6850 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
SP2
PCI
Express Emulex: LP1050Ex−E2, 5, 6, 15, 27, 28, 35,
LPe111−E2, 4, 5, 6, 15, 35, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
281 IBM xSeries: x3850M2 (7233, 7234), x3950M2
(7233, 7234) Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
SP2
PCI
Express Emulex: LPe11000−E2, 5, 6, 15, 35, 45,
LPe11002−E2, 5, 6, 15, 35, 45,
LPe12000−E2, 5, 15, 35, 36, LPe12002−E2,
5, 15, 35, 36;
IBM: 42C2069 (LPe11000)2, 5, 6, 15, 35, 45,
42C2071 (LPe11002)2, 5, 6, 15, 35, 45,
42D0485 (LPe12000)5, 6, 15, 35, 36, 63,
42D0494 (LPe12002)5, 6, 15, 35, 36, 62
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26, 40 See31
282 HPQ Proliant DL785 (G5) Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
SP2
PCI
Express Emulex: LPe11002−E2, 5, 6, 15, 35, 45,
LPe1150−E2, 5, 6, 15, 35, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 40
283 IBM xSeries x3455 (7940) Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
SP2
PCI
Express Emulex: LPe111−E2, 5, 6, 15, 35, 45,
LPe1150−E2, 5, 6, 15, 24, 35, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
CLARiiON AX150
03/04/2009 161 CLARiiON AX150