SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
499 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4, SR6850HW4;
Digital Henge INNO: HR−4850, HR−4850T, HR−6850,
HR−6850T;
Digital Henge SH4500R4;
Fujitsu Siemens Primergy RX330;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
IBM xSeries: x336 (8837)78, x346 (8840), x3800/x260
(8865)82, 83, x3850/x366 (8863)82, 83, x3950/x3950E/x460
(8872, 8874)82, 83, x3950/x3950E/x460 (8878, 8879);
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004, G5;
Lenovo SureServer: R650, R650 G5, T630 6003, T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: SS210, SS370, SS3840, ZSS230−D,
ZSS230−T;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI−X QLogic
QLA2340−E−SP1, 36, 56 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
500 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI−X QLogic
QLA2340−E−SP1, 36, 56 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
501 Dell PowerEdge: 1950, 6800, 6850 SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI−X QLogic
QLA2340−E−SP1, 42, 56 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
502 Fujitsu Siemens Primergy: RX330, RX600 S2, TX600 S2;
Hewlett Packard Proliant DL360: (G4), (G4p);
IBM xSeries x3950/x3950E/x460 (8878, 8879)
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI−X QLogic
QLA2340−E−SP36, 56 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
503 IBM xSeries x3950/x3950E/x460 (8878, 8879) SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI−X QLogic
QLA2460−E−SP1, 13, 56 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
504 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI−X QLogic
QLE2460−E−SP1, 13, 56 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
505 Acer Altos R710;
Anders & Rodewyk Ariane: 145, 245;
Aquarius AquaServer TD322;
BGM Elitas: SR510, SR710;
Compusys ProManaged: SR1400JR2, SR2400JR2;
Digital Henge Revo: JS1400, JS2400;
Gateway: E−9415R, E−9515R;
Intel: SR1400/SE7520JR2, SR2400/SE7520JR2;
MPC NetFRAME: 1720, 2720;
MaxData Platinum: 1500 IR M5, 2200 IR M5;
Nanobay: JR1400, JR2400;
Ockam OS−7000;
PowerLeader: PR1700, PR1700 G2, PR2700, PR2700
G2;
R−Style MARSHALL: NP281r, NP282r;
Samsung ZSS150;
Verari RM2205;
Wortmann TERRA AQUA: 6200, 6300, 6500
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI−X114 Emulex: LP101−E1, 10,
53, 55, LP1050−E1, 9, 10,
53, LP982−E1, 53, 54, 55;
QLogic
QLA2340−E−SP1, 36, 56
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 834 CLARiiON AX150