Microsoft Windows 2008 [x86]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
213 Dell PowerEdge: 1900, 1950 III, 2900, 2900 III,
2950, 2950 III, 2970, 6950;
HPQ Proliant: DL320 (G5), DL360 (G5), DL365,
DL385 (G2), DL385 (G5), DL585 (G2), ML350
(G5)27, ML370 (G5)27, ML570 (G4)27
Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
QLogic QLE2462−E−SP7, 9,
10, 12, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17, 25 See16
214 IBM xSeries x3655: (7943), (7985);
IBM xSeries x3755 (7163)
Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
QLogic: QLA200−E−SP7, 9,
10, 53, QLA200−E−SP7, 10,
53, QLA210−E−SP9, 10, 12,
53, QLA210−E−SP10, 12, 53,
QLA2340−E−SP7, 9, 10, 26,
QLA2340−E−SP7, 10, 26
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17, 25 See16
215 IBM xSeries: x3550 (7978), x3650 (7979), x3755
(8877) Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
QLogic: QLE2560−E−SP7,
9, 12, 18, QLE2562−E−SP7,
9, 12, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17, 25 See16, 21
216 HPQ Proliant: DL320 (G5), DL360 (G5), DL365,
DL385 (G2), DL385 (G5), DL585 (G2), ML350
(G5)27, ML370 (G5)27, ML570 (G4)27;
IBM xSeries x3655: (7943), (7985);
IBM xSeries x3755 (7163)
Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
QLogic: QLE2560−E−SP9,
12, 18, QLE2562−E−SP9, 12,
18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17, 25 See16, 21
217 Dell PowerEdge 1855 Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI−X Dell 2342M7, 9, 10, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
218 Dell PowerEdge 6850 Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI−X Dell 2362M9, 10, 89, 90 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
219 Intel: SC5300AF2, SE7520BB2 Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI−X Emulex LP10000−E7, 15, 19,
22, 28 FC−AL,
FC−SW EMC
CLARiiON
AX150
N See21
220 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4,
SR6850HW4;
Digital Henge INNO: HR−4850, HR−4850T,
HR−6850, HR−6850T;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R630 G5, R650, R650 G5,
T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: ZSS230−D, ZSS230−T;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI−X Emulex LP10000−E7, 19, 22,
28 FC−AL,
FC−SW EMC
CLARiiON
AX150
N See21
CLARiiON AX150
03/04/2009 264 CLARiiON AX150