Microsoft Windows 2008 [x64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
206 IBM xSeries x3850/x366 (8864) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
IBM: 39R6525 (QLE2460)3,
10, 12, 13, 39R6527
(QLE2462)3, 10, 12, 13;
QLogic QLE2462−E−SP3,
10, 12, 13
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9 See11
207 IBM xSeries x3755 (7163) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
IBM: 39R6525 (QLE2460)3,
10, 12, 13, 39R6527
(QLE2462)3, 10, 12, 13;
QLogic: QLE220−E−SP3,
12, 13, 18, QLE220−E−SP3,
10, 12, 13, 18,
QLE2360−E−SP13, 17, 18,
QLE2460−E−SP3, 12, 13, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See11
208 IBM xSeries x3655 (7943) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
IBM: 39R6525 (QLE2460)3,
10, 12, 13, 39R6527
(QLE2462)3, 10, 12, 13;
QLogic: QLE220−E−SP3,
12, 13, 18, QLE220−E−SP3,
10, 12, 13, 18,
QLE2360−E−SP10, 13, 17,
18, QLE2460−E−SP3, 12, 13,
18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See11
209 IBM xSeries x3655: (7943), (7985) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
IBM: 42D0485
(LPe12000)2, 3, 21, 23, 25, 27,
42D0494 (LPe12002)2, 3,
21, 23, 25, 26, 42D0501
(QLE2560)3, 10, 12, 29,
42D0510 (QLE2562)3, 10,
12, 28;
QLogic: QLE2560−E−SP3,
10, 12, QLE2562−E−SP3, 10,
12
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9, 24 See6, 11
210 NEC Express 5800: 120Lj, 120Rh−1, 120Rj−2 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
NEC N8190−131
(LPe11002)4, 5, 18, 43, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 47, 59 See6
211 NEC Express 5800: 120Lj, 120Rh−1, 120Rj−2 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
NEC: N8190−120
(LP1050)4, 5, 18, 57, 67, 68,
N8190−127 (LPe1150)4, 5,
43, 57, 70
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 47, 59 See6, 11
212 Dell PowerEdge: 1900, 2900, 2950;
HPQ Proliant: DL320 (G5), DL360 (G5), DL365,
DL385 (G2), DL385 (G5), DL585 (G2), DL585 (G5),
ML350 (G5)31, ML370 (G5)31, ML570 (G4)31
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
QLogic QLA2340−E−SP10,
13, 18, 19 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See11
213 HPQ Proliant DL580 (G5) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
QLogic QLA2340−E−SP10,
13, 18, 19 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 47 See11
214 Dell PowerEdge: 1900, 2900, 2950;
HPQ Proliant: DL320 (G5), DL360 (G5), DL365,
DL385 (G2), DL385 (G5), DL585 (G2), ML350
(G5)31, ML370 (G5)31, ML570 (G4)31
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
QLogic QLA2342−E−SP10,
13, 18, 19 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See11
215 HPQ Proliant DL585 (G5);
IBM xSeries x3655: (7943), (7985);
IBM xSeries x3755 (7163)
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
QLogic QLA2460−E−SP3,
10, 12, 13, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See11
216 HPQ Proliant: DL365, DL385 (G2), DL385 (G5),
DL585 (G5);
Hewlett Packard Proliant DL360: (G4), (G4p);
IBM xSeries x3655 (7943)
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
QLogic QLE2460−E−SP3,
10, 12, 13, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See11
217 HPQ Proliant: DL365, DL385 (G2), DL385 (G5);
Hewlett Packard Proliant DL360: (G4), (G4p)
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
QLogic QLE2462−E−SP3,
10, 12, 13, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See11
218 IBM xSeries x3755 (7163) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express,
PCI−X
QLogic: QLA200−E−SP13,
18, 32, QLA200−E−SP10, 13,
18, 32, QLA210−E−SP3, 13,
32, QLA210−E−SP3, 10, 13,
32
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9 See11
CLARiiON AX150
03/04/2009 230 CLARiiON AX150