VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
161 HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)33;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X HPQ: AD167A/FC2143 (LP1150)1, 2, 12, 26,
AD168A/FC2243 (LP11002)1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
162 HPQ Proliant BL45p VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X HPQ: Dual−port Fibre Channel Adapter for HP
Proliant BL25p/BL45p 381881−B2122, 29,
Emulex−based BL25/30/35/45p Fibre Channel
Mezzanine HBA − 394588−B212, 23, 26
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
163 HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)33, ML570 (G3)33;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X HPQ: FCA2214/281541−B21 (QLA2340)29, 38,
FCA2214DC/321835−B21 (QLA2342)29, 38 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
164 IBM xSeries: x235, x365,
x3800/x260 (8865)65, x3850/x366
(8863)65, x3950/x3950E/x460
(8872, 8874)65,
x3950/x3950E/x460 (8878, 8879)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM: 19K1246 (QLA2310)29, 38, 79, 24P0960
(QLA2340)29, 38, 63 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
165 IBM xSeries: x3800/x260
(8865)65, x3950/x3950E/x460
(8872, 8874)65,
x3950/x3950E/x460 (8878, 8879)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM: 39M5894 (QLA2460)12, 29, 32, 39M5895
(QLA2462)12, 32, 80 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
166 NEC Express 5800: 120Rh−2,
140Rd−4 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X NEC N8190−120 (LP1050)2, 26, 35, 61 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
167 NEC Express 5800 120Lh VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X NEC N8190−120 (LP1050)2, 26, 61, 85 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
168 NEC Express 5800 120Ba−4 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X NEC N8403−015 (LP1050DC)2, 26, 61, 85 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 86
169 Dell PowerEdge: 1750, 2600,
2650, 6650;
HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)33, ML570 (G3)33;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365,
xSeries x3800/x260 (8865)65,
xSeries x3850/x366 (8863)65,
xSeries x3950/x3950E/x460
(8872, 8874)65, xSeries
x3950/x3950E/x460 (8878, 8879)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X QLogic QLA2200F−EMC29, 41 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
170 HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)33, ML570 (G3)33;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365,
xSeries x3800/x260 (8865)65,
xSeries x3850/x366 (8863)65,
xSeries x3950/x3950E/x460
(8872, 8874)65, xSeries
x3950/x3950E/x460 (8878, 8879);
Sun Sun Fire V40z
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X QLogic QLA2310F−E−SP29, 38, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
171 Fujitsu Siemens Primergy: RX600
S2, TX600 S2;
HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)33, ML570 (G3)33;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365,
xSeries x3800/x260 (8865)65,
xSeries x3850/x366 (8863)65,
xSeries x3950/x3950E/x460
(8872, 8874)65, xSeries
x3950/x3950E/x460 (8878, 8879);
Sun Sun Fire: V40z, X4100,
X4200
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X QLogic QLA2340−E−SP29, 38, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
172 HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)33, ML570 (G3)33;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365,
xSeries x3800/x260 (8865)65,
xSeries x3850/x366 (8863)65,
xSeries x3950/x3950E/x460
(8872, 8874)65, xSeries
x3950/x3950E/x460 (8878, 8879);
Sun Sun Fire: V40z, X4100,
X4200
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X QLogic QLA2342−E−SP29, 38, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150
03/04/2009 871 CLARiiON AX150