VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
208 HPQ Proliant DL785 (G5) VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express HPQ: A8002A/FC2142SR (LPe1150)1, 2, 12, 26,
A8003A/FC2242SR (LPe11002)1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
209 IBM xSeries: x3455 (7984)104,
x3850M2 (7141)105, 106,
x3850M2 (7233, 7234)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express IBM: 39R6525 (QLE2460)12, 29, 32, 39R6527
(QLE2462)12, 29, 32 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
210 IBM xSeries: x3455 (7984)104,
x3850M2 (7233, 7234), x3950M2
(7233, 7234)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express IBM: 42C2069 (LPe11000)1, 2, 12, 26, 42C2071
(LPe11002)1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
211 Dell PowerEdge: 1850, 1950,
1950 III, 2800, 2850, 2900 III,
2950 III, 2970, 6800, 6850, R805,
R900, R905;
HPQ Proliant DL785 (G5)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express QLogic QLE2560−E−SP12, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
212 Dell PowerEdge 1950;
IBM xSeries x3455 (7984)104 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express QLogic: QLE2360−E−SP12, 29, 50,
QLE2362−E−SP12, 29, 50 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
213 Dell PowerEdge: 1850, 1950,
1950 III, 2800, 2850, 2900 III,
2950 III, 2970, 6800, 6850;
HPQ Proliant DL785 (G5)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express QLogic: QLE2460−E−SP12, 29, 32, 59,
QLE2462−E−SP12, 29, 59 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
214 HPQ Proliant DL785 (G5);
IBM xSeries: x3455 (7984)104,
x3850M2 (7141)105, 106,
x3850M2 (7233, 7234)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express QLogic: QLE2460−E−SP12, 29, 32,
QLE2462−E−SP12, 29, 32 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
215 Dell PowerEdge: 2850, 6850;
HPQ Proliant: DL385 (G2), DL585
(G2)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex LP10000ExDC−E2, 12, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
216 HPQ Proliant ML370 (G5)33 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex LP1050−E2, 12, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
217 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850, 6950;
HPQ Proliant DL360 (G5)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex LP1050Ex−E2, 12, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
218 Dell PowerEdge: 2900, 2950,
6950;
HPQ Proliant: DL385 (G2), DL585
(G2)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex LPe11000−E1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
219 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850, 6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LP10000−E2, 23, 26, LP10000DC−E2,
23, 26, LP8000−EMC26, 37, 42, LP9002−E
(LP9002L−E)2, 26, 37, LP9802−E2, 26, 35, 36,
LP9802DC−E2, 23, 26, 34, LP982−E2, 23, 26, 34
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
220 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850, 6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LP1050−E2, 23, 26, LP1050DC−E2, 23,
26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
221 HPQ Proliant: DL385 (G2), DL585
(G2) VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LP11000−E1, 2, 12, 26, 31, LP11002−E1,
2, 12, 26, 31 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
222 Dell PowerEdge: 2900, 2950,
6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LPe11002−E1, 2, 12, 26, LPe1150−E1, 2,
12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
223 HPQ Proliant: DL360 (G5), DL585
(G2), ML370 (G5)33 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
HPQ: A8002A/FC2142SR (LPe1150)1, 2, 12, 26,
A8003A/FC2242SR (LPe11002)1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
224 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
HPQ: AB429A/FC1143 (QLA2460)12, 29, 32,
AD167A/FC2143 (LP1150)1, 2, 12, 26,
AD168A/FC2243 (LP11002)1, 2, 12, 26,
AE311A/FC1142SR (QLE2460)12, 29, 32,
AE312A/FC1242SR (QLE2462)12, 29, 32,
AE369A/FC1243 (QLA2462)12, 29, 32,
FCA2214/281541−B21 (QLA2340)29, 38,
FCA2214DC/321835−B21 (QLA2342)29, 38;
QLogic: QLA2340−E−SP29, 38, 39,
QLA2342−E−SP29, 38, 39, QLA2460−E−SP12, 29,
32, QLA2462−E−SP12, 29, 32
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
225 Dell PowerEdge: 1850, 2850,
2900, 2950, 6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
QLogic QLA2200F−EMC29, 41 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
226 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2) VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
QLogic QLA2310F−E−SP29, 38, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
227 Dell PowerEdge: 1950 III, 2900,
2900 III, 2950, 2950 III, 2970,
6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
QLogic QLE2560−E−SP12, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 874 CLARiiON AX150