Red Hat RHEL [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
556 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant DL585 (G2);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI
Express,
PCI−X
Emulex LPe12000−E3, 12,
13, 85;
QLogic: QLE2560−E−SP3,
20, 101, QLE2562−E−SP3,
20, 101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
557 Dell PowerEdge: 1900, 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950 Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI
Express,
PCI−X
Emulex LPe12002−E3, 12,
13, 85 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See1
558 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)63, ML370 (G5)63, ML570
(G3)63, ML570 (G4)63;
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7943),
x3655 (7985), x3755 (7163), x3755 (8877)
Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI
Express,
PCI−X
Emulex LPe12002−E3, 13,
85 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See1
559 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)63, ML370 (G5)63, ML570
(G3)63, ML570 (G4)63
Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI
Express,
PCI−X
Emulex LPe1250−E3, 13, 85 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See1
560 IBM xSeries x3655 (7943) Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI
Express,
PCI−X
Emulex:
LP10000ExDC−E3, 12, 13,
15, LP1050Ex−E3, 12, 13, 15;
IBM: 39M5894 (QLA2460)3,
20, 101, 39M5895
(QLA2462)3, 20, 101,
42C2069 (LPe11000)3, 12,
13, 14, 42C2071
(LPe11002)3, 12, 13, 14;
QLogic: QLA2460−E−SP3,
20, 101, QLE2360−E−SP3,
34, 46, 101,
QLE2460−E−SP3, 20, 101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See1
561 Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2 Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI
Express,
PCI−X
Emulex: LPe12000−E3, 12,
13, 85, LPe12002−E3, 12, 13,
85, LPe12002−E3, 13, 85
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17 See1, 21
562 Anders & Rodewyk Ariane 540;
BGM Elitas: SP520, SP720;
Compusys ProManaged: 5299XN, SC5400PSL;
Digital Henge Revo: LP5299, LS5400;
HCL Infiniti Global Line 2700: OW, SO, ST;
Intel: SC5299/SC5400/S5000PSLROMB,
SR2520/S5000VSA;
MPC NetFRAME 640;
Nanobay Nano: SL5299, SL5400;
Ockam Duo OSPSL−4200;
Wipro NetPower Z2503;
Wortmann TERRA SERVER: 6401, 6501
Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI
Express,
PCI−X
Emulex: LPe12000−E3, 12,
13, 85, LPe12002−E3, 12, 13,
85, LPe1250−E3, 12, 13, 85;
QLogic: QLA2460−E−SP3,
20, 101, QLE2560−E−SP3,
20, 101, QLE2562−E−SP3,
20, 101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17 See21
563 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI
Express,
PCI−X
Emulex: LPe12002−E3, 12,
13, 85, LPe1250−E3, 12, 13,
85
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 676 CLARiiON AX150