Oracle Enterprise Linux [x86_64]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
346 Dell PowerEdge: 1950, 1950 III, 2900 III, 2950 III, 2970,
R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
HPQ Proliant DL785 (G5);
IBM xSeries x3850M2: (7141)32, (7233, 7234);
IBM xSeries x3950M2: (7141)32, (7233, 7234);
Sun Sun Fire: X2200−M2, X4140, X4150, X4240, X4250,
X4440, X4450
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex LPe11002−E7, 8, 9, 10 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
347 Dell PowerEdge: 1800, 1850, 1950, 1950 III, 2800, 2850,
2900 III, 2950 III, 2970, 6800, 6850, R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
HPQ Proliant DL785 (G5)
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex LPe1150−E7, 8, 9, 10 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
348 Dell PowerEdge: R805, R900, R905;
HPQ Proliant DL785 (G5);
IBM xSeries: x3350 (4192,4193), x3455 (7940), x3455
(7984), x3850M2 (7141)32, x3850M2 (7233, 7234),
x3950M2 (7141)32, x3950M2 (7233, 7234);
Sun Sun Fire: X2200−M2, X4140, X4150, X4240
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex LPe12000−E7, 8, 10, 57;
QLogic: QLE2560−E−SP10, 21, 38,
QLE2562−E−SP10, 21, 38
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14, 36
349 Dell PowerEdge: R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
HPQ Proliant DL785 (G5);
IBM xSeries x3850M2: (7141)32, (7233, 7234);
IBM xSeries x3950M2: (7141)32, (7233, 7234);
Sun Sun Fire: X2200−M2, X4140, X4150, X4240
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex LPe12002−E7, 8, 10, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14, 36
350 Fujitsu Siemens Primergy RX300 S4;
HPQ Proliant DL785 (G5);
IBM xSeries: x3350 (4192,4193), x3455 (7940), x3455
(7984), x3850M2 (7141)32, x3850M2 (7233, 7234),
x3950M2 (7141)32, x3950M2 (7233, 7234);
Sun Sun Fire: X2200−M2, X4140, X4150, X4240
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex LPe12002−E8, 10, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14, 36
351 Digital Henge INNO FS7000;
Fujitsu Siemens Primergy RX300 S4;
HCL Infiniti Global Line 4700 FC;
Intel S7000FC4UR;
LangChao NF520D2;
Lenovo SureServer R630 G7;
PowerLeader PR4850Q;
Samsung ZSS232;
Wipro NetPower Z4402
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex LPe1250−E7, 8, 10, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See36
352 Fujitsu Siemens Primergy RX300 S4 Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex LPe1250−E8, 10, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14, 36
353 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800,
6850 Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex: LP1050Ex−E7, 8, 10, 59,
LPe111−E7, 8, 10, 41, 42 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
354 Digital Henge INNO FS7000;
HCL Infiniti Global Line 4700 FC;
Intel S7000FC4UR;
LangChao NF520D2;
Lenovo SureServer R630 G7;
PowerLeader PR4850Q;
Samsung ZSS232;
Wipro NetPower Z4402
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex: LPe111−E7, 8, 9, 10,
LPe1150−E7, 8, 9, 10 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6
355 Digital Henge INNO FS7000;
HCL Infiniti Global Line 4700 FC;
Intel S7000FC4UR;
LangChao NF520D2;
Lenovo SureServer R630 G7;
PowerLeader PR4850Q;
Samsung ZSS232;
Wipro NetPower Z4402
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex: LPe12000−E7, 8, 10, 57,
LPe12002−E7, 8, 10, 57;
QLogic: QLE2360−E−SP38, 74,
QLE2560−E−SP10, 21, 38,
QLE2562−E−SP10, 21, 38
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See36
356 Dell PowerEdge: 1950, 1950 III, 2900 III, 2950 III, 2970,
6800, 6850, R805, R900, R905 Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Emulex: LPe12000−E7, 8, 10, 57,
LPe12002−E7, 8, 10, 57;
QLogic: QLE2560−E−SP10, 21, 38,
QLE2562−E−SP10, 21, 38
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
357 HPQ Proliant DL785 (G5) Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express HPQ: A8002A/FC2142SR (LPe1150)7,
8, 9, 10, AE311A/FC1142SR
(QLE2460)10, 21, 38,
AE312A/FC1242SR (QLE2462)10, 21,
38
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
358 HPQ Proliant: BL260c G5 (quad core processor)95,
BL2x220c G5 (quad core processor)95, BL460c (dual core
processor)95, BL460c (quad core processor)95, BL465c
(dual core processor)95, BL465c G5 (quad core
processor)95, BL480c (dual core processor)95, BL480c
(quad core processor)95, BL495c G5 (quad core
processor), BL680c (G5)95, BL685c (dual core
processor)95, BL685c G5 (quad core processor)95
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express HPQ: Emulex LPe1105−HP 4Gb FC
HBA for HP c−Class Bladesystem
(403621−B21)8, 42, 97, QLogic
QMH2462 4Gb FC HBA for HP
c−Class Bladesystem
(403619−B21)38, 96
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6
CLARiiON AX150
03/04/2009 390 CLARiiON AX150