SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
391 HPQ Proliant: DL380 (G5), DL580 (G4) SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI, PCI
Express,
PCI−X
Emulex: LP101−E1, 10,
55, 61, LP1050−E10, 55,
61, LP11000−E1, 10, 11,
61, LP982−E54, 55, 61,
LPe111−E1, 10, 11, 61;
HPQ:
A8002A/FC2142SR
(LPe1150)1, 10, 11, 61,
AB429A/FC1143
(QLA2460)1, 13, 17,
AE311A/FC1142SR
(QLE2460)1, 13, 17,
AE312A/FC1242SR
(QLE2462)1, 13, 17;
QLogic:
QLA2460−E−SP1, 13, 17,
QLA2462−E−SP1, 13, 17,
QLE220−E−SP1, 2, 39,
110, QLE220−E−SP1, 16,
17
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
392 Fujitsu Siemens Primergy TX200 S4 SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI, PCI
Express,
PCI−X
Emulex: LPe1150−E1, 10,
11, 61, 120, LPe1150−E1,
10, 11, 61, 120, 121,
LPe1150−E1, 10, 11, 61,
120, 121, 122,
LPe1150−E1, 10, 11, 61,
120, 122, LPe1150−E1, 10,
11, 61, 121, LPe1150−E1,
10, 11, 61, 121, 122,
LPe1150−E1, 10, 11, 61,
122
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
393 Fujitsu Siemens Primergy TX200 S3;
HPQ Proliant: DL380 (G5), DL580 (G4) SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI, PCI
Express,
PCI−X
QLogic
QLA2340−E−SP17, 36 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
394 Dell PowerEdge: 1800, 2800 SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI, PCI
Express,
PCI−X
QLogic QLE220−E−SP1,
2, 110 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
395 Fujitsu Siemens Primergy TX200: S3, S4 SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI, PCI
Express,
PCI−X
QLogic
QLE2460−E−SP13 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
396 Fujitsu Siemens Primergy TX200: S3, S4 SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI, PCI
Express,
PCI−X
QLogic:
QLE2460−E−SP1, 13, 17,
QLE2460−E−SP1, 13, 17,
18, QLE2460−E−SP1, 13,
17, 18, 19,
QLE2460−E−SP1, 13, 17,
18, 19, 62,
QLE2460−E−SP1, 13, 17,
18, 62, QLE2460−E−SP1,
13, 17, 19,
QLE2460−E−SP1, 13, 17,
19, 62, QLE2460−E−SP1,
13, 17, 62
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See22
397 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850;
HPQ Proliant: DL380 (G4), DL385, DL585, ML370 (G4)40
SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI,
PCI−X Emulex LP101−E1, 10, 55,
61 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
398 Fujitsu Siemens Primergy RX800 S2 SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI,
PCI−X Emulex LP1050−E1, 10,
53, 55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
399 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850;
Fujitsu Siemens Primergy RX800 S2
SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI,
PCI−X Emulex LP1050−E1, 10,
55, 61 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
400 Fujitsu Siemens Primergy RX800 S2 SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI,
PCI−X Emulex LP1050−E10, 55,
59, 61 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y48, 49
401 HPQ Proliant: DL145, DL380 (G4), DL385, DL585, ML370
(G4)40 SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI,
PCI−X Emulex LP11000−E1, 10,
11, 61;
QLogic:
QLA2460−E−SP1, 13, 17,
QLA2462−E−SP1, 13, 17
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
402 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850 SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI,
PCI−X Emulex LP982−E1, 54, 55,
61;
QLogic
QLA2340−E−SP17
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
403 HPQ Proliant: DL380 (G4), DL385, DL585, ML370 (G4)40 SuSE
SLES
[x86_64]
105, 6, 7, 20,
21
PCI,
PCI−X Emulex: LP1050−E10, 55,
61, LP982−E54, 55, 61 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 818 CLARiiON AX150