VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
408 IBM xSeries: x3655 (7943), x3755
(7163);
Sun Sun Fire X4600−M2
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
QLogic: QLE2460−E−SP12, 29, 32,
QLE2460−E−SP29, 32, QLE2462−E−SP12, 29, 32 FC−SW EMC
CLARiiON
AX150
Y
409 Sun Sun Fire X4600−M2 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Sun: SG−XPCI1FC−QF4 (QLA2460)12, 29, 59,
SG−XPCI2FC−QF4 (QLA2462)12, 29, 59,
SG−XPCIE1FC−QF4 (QLE2460)12, 29, 59,
SG−XPCIE2FC−QF4 (QLE2462)12, 29, 59
FC−SW EMC
CLARiiON
AX150
Y
410 IBM BladeCenter: HS20 (Model
7981), HS21 (Model 8853), HS21
XM (Model 7995), LS21 (Model
7971), LS41 (Model 7972)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM Emulex 4Gb SFF Fibre Channel Exp Card
(39Y9186)1, 12, 26, 77 FC−SW EMC
CLARiiON
AX150
Y13, 14
411 IBM BladeCenter HS20 (Model:
7981), 8832)64, 8832−N1X),
8843);
IBM BladeCenter LS20 (Model
8850)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM Emulex LP1005DC FC Exp Card2, 12, 23, 26 FC−SW EMC
CLARiiON
AX150
Y13, 14
412 IBM BladeCenter HS20 (Model:
7981), 8843);
IBM BladeCenter HS21: (Model
8853), XM (Model 7995);
IBM BladeCenter: LS21 (Model
7971), LS41 (Model 7972)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM HS20 4GB SFF FC Exp Card
(26R0890/26R0893)12, 29, 76 FC−SW EMC
CLARiiON
AX150
Y13, 14
413 IBM BladeCenter: HS20 (Model
7981), HS21 (Model 8853) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM HS20 FC Exp Card (13N2203/26R0836)12,
29, 75 FC−SW EMC
CLARiiON
AX150
Y13, 14
414 IBM BladeCenter HS20 (Model:
7981), 8832)64, 8832−N1X) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM HS20 FC Exp Card (13N2203/26R0836)29,
69 FC−SW EMC
CLARiiON
AX150
Y13, 14
415 IBM BladeCenter: HS20 (Model
8843), HS21 XM (Model 7995),
LS21 (Model 7971), LS41 (Model
7972)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM HS20 FC Exp Card (26K4841/26K4859)12,
29, 68, 69 FC−SW EMC
CLARiiON
AX150
Y13, 14
416 IBM BladeCenter HS20 (Model:
7981), 8832)64, 8832−N1X),
8843);
IBM BladeCenter HS21 (Model
8853)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM HS20 FC Exp Card (48P7061/26R0836)12,
29 FC−SW EMC
CLARiiON
AX150
Y13, 14
417 IBM BladeCenter HS21 (Model
8853) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM QLogic 4gb FC Exp Card (CFFv,
41Y8527)12, 80, 108 FC−SW EMC
CLARiiON
AX150
Y13, 14
418 IBM BladeCenter: HS21 XM
(Model 7995), LS21 (Model
7971), LS41 (Model 7972)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM QLogic: 4gb FC Exp Card (CFFv,
41Y8527)12, 29, Ethernet and 4gb FC Exp Card
(CFFh, 39Y9306)12, 29, 87
FC−SW EMC
CLARiiON
AX150
Y13, 14
419 IBM BladeCenter LS20 (Model
8850) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card
(39Y9186)1, 12, 26, HS20 FC Exp Card
(13N2203/26R0836) for IBM eServer LS2012, 29,
69, HS20 FC SFF Exp Card (26K4841) for IBM
eServer LS2012, 29
FC−SW EMC
CLARiiON
AX150
Y13, 14
420 Fujitsu Siemens Primergy TX200:
S3, S4;
HPQ Proliant: DL380 (G5), DL580
(G4), DL580 (G5)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex: LPe12000−E12, 26, 78, LPe12002−E12,
26, 78 FC−SW EMC
CLARiiON
AX150
Y13, 14
421 Fujitsu Siemens Primergy TX200
S4;
HPQ Proliant DL380: (G4), (G5);
HPQ Proliant DL580: (G3)33,
(G4), (G5);
HPQ Proliant ML370 (G4)33
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI, PCI
Express,
PCI−X
QLogic QLE2562−E−SP12, 29 FC−SW EMC
CLARiiON
AX150
Y
422 Dell PowerEdge: R805, R900,
R905;
HPQ Proliant DL785 (G5)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express Emulex: LPe11002−E1, 2, 12, 26, LPe1150−E1, 2,
12, 26 FC−SW EMC
CLARiiON
AX150
Y13, 14
423 Dell PowerEdge: 1850, 1950,
1950 III, 2800, 2850, 2900 III,
2950 III, 2970, 6800, 6850, R805,
R900, R905;
HPQ Proliant DL785 (G5);
IBM xSeries x3455 (7984)104
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express Emulex: LPe12000−E12, 26, 78, LPe12002−E12,
26, 78 FC−SW EMC
CLARiiON
AX150
Y13, 14
424 IBM xSeries x3455 (7984)104 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express IBM: 42D0485 (LPe12000)12, 26, 101, 42D0494
(LPe12002)12, 26, 100, 42D0501 (QLE2560)12,
97, 99, 42D0510 (QLE2562)12, 97, 98
FC−SW EMC
CLARiiON
AX150
Y13, 14
425 IBM xSeries x3850M2: (7141)105,
106, (7233, 7234) VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express IBM: 42D0485 (LPe12000)12, 26, 101, 42D0494
(LPe12002)12, 26, 100, 42D0501 (QLE2560)12,
97, 99, 42D0510 (QLE2562)12, 97, 98
FC−SW EMC
CLARiiON
AX150
Y
426 HPQ Proliant DL785 (G5);
IBM xSeries: x3455 (7984)104,
x3850M2 (7141)105, 106,
x3850M2 (7233, 7234), x3950M2
(7233, 7234)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express QLogic QLE2560−E−SP12, 29 FC−SW EMC
CLARiiON
AX150
Y
427 Dell PowerEdge: 1850, 1950,
1950 III, 2800, 2850, 2900 III,
2950 III, 2970, 6800, 6850, R805,
R900, R905;
HPQ Proliant DL785 (G5);
IBM xSeries: x3455 (7984)104,
x3850M2 (7141)105, 106,
x3850M2 (7233, 7234), x3950M2
(7233, 7234)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express QLogic QLE2562−E−SP12, 29 FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 886 CLARiiON AX150