Red Hat RHEL [32−Bit]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
991 Sun Sun Blade Server Module X6240 Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express Sun:
SG−XPCIE2FC−EB4−Z
(LPem11002)3, 17, 37, 103,
SG−XPCIE2FC−QB4−Z
(QEM2462)1, 3, 30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See27
992 Sun Sun Blade Server Module: X6220, X6250, X6450,
X8440 Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express Sun:
SG−XPCIE2FC−EB4−Z
(LPem11002)3, 17, 37, 103,
SG−XPCIE2FC−QB4−Z
(QEM2462)1, 3, 30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
993 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL385 (G5), DL585 (G2), DL585 (G5), ML350
(G5)47, ML370 (G5)47, ML570 (G3)47, ML570 (G4)47;
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7943),
x3655 (7985), x3755 (7163), x3755 (8877), x3800/x260
(8866), x3850/x366 (8864);
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LP11000−E3, 12, 16,
17, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
994 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)47, ML370 (G5)47, ML570
(G3)47, ML570 (G4)47;
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7943),
x3655 (7985), x3755 (7163), x3755 (8877), x3800/x260
(8866), x3850/x366 (8864);
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LP11000−E3, 12, 17,
103 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
995 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL385 (G5), DL585 (G2), DL585 (G5), ML350
(G5)47, ML370 (G5)47, ML570 (G4)47
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LP1150−E3, 12, 16,
17, 18;
HPQ: AB429A/FC1143
(QLA2460)1, 3, 31,
AE311A/FC1142SR
(QLE2460)1, 3, 31,
AE312A/FC1242SR
(QLE2462)1, 3, 31,
AE369A/FC1243
(QLA2462)1, 3, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
996 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)47, ML370 (G5)47, ML570
(G4)47
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LP1150−E3, 12, 17,
103;
HPQ: AB429A/FC1143
(QLA2460)1, 3, 30, 31,
AE311A/FC1142SR
(QLE2460)1, 3, 30, 31,
AE312A/FC1242SR
(QLE2462)1, 3, 30, 31,
AE369A/FC1243
(QLA2462)1, 3, 30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
997 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL385 (G5), DL585 (G2), DL585 (G5), ML350
(G5)47, ML370 (G5)47, ML570 (G3)47, ML570 (G4)47;
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe11000−E3, 12,
16, 17, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
998 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)47, ML370 (G5)47, ML570
(G3)47, ML570 (G4)47;
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe11000−E3, 12,
17, 103 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
999 Fujitsu Siemens Primergy: BX620 S4, RX200 S3, RX200
S4, RX600 S3, RX600 S4, TX300 S3, TX300 S4, TX600
S3;
HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL385 (G5), DL585 (G2), DL585 (G5), ML350
(G5)47, ML370 (G5)47, ML570 (G3)47, ML570 (G4)47;
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe11002−E3, 12,
17 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
1000 Fujitsu Siemens Primergy: BX620 S4, RX200 S3, RX200
S4, RX600 S3, RX600 S4, TX300 S3, TX300 S4, TX600
S3;
HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)47, ML370 (G5)47, ML570
(G3)47, ML570 (G4)47;
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe11002−E3, 12,
17, 103 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
1001 Fujitsu Siemens Primergy: BX620 S4, RX200 S3, RX200
S4, RX600 S3, RX600 S4, TX300 S3, TX300 S4, TX600
S3
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe1150−E3, 12, 17,
103 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
1002 HPQ Proliant DL320 (G5) Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe1150−E3, 12, 17,
103 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y33
1003 Dell PowerEdge: 1900, 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950;
HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)47, ML370 (G5)47, ML570
(G3)47, ML570 (G4)47;
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7943),
x3655 (7985), x3755 (7163), x3755 (8877)
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI
Express,
PCI−X
Emulex LPe12000−E3, 17,
45, 103 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See27
CLARiiON AX150