SuSE SLES [32−Bit]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
216 Fujitsu Siemens Primergy TX200 S4 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI, PCI
Express,
PCI−X
Emulex LPe12002−E12, 40, 77 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y74 See42, 55
217 Fujitsu Siemens Primergy TX200 S4 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI, PCI
Express,
PCI−X
Emulex LPe1250−E11, 12, 40, 77 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y74 See55
218 HPQ Proliant DL580 (G5) SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI, PCI
Express,
PCI−X
Emulex: LP10000ExDC−E11, 12, 40, 41,
LP1050Ex−E11, 12, 40, 41, LP11000−E11, 12, 17, 18,
40, LPe11000−E11, 12, 18, 40, 78, LPe11002−E11, 12,
17, 18, 40;
QLogic QLA2462−E−SP2, 12, 35
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31, 50,
51
219 HPQ Proliant DL580 (G5) SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI, PCI
Express,
PCI−X
Emulex: LP1050−E11, 12, 40, 41, LP1150−E11, 12,
17, 18, 40, LPe12000−E11, 12, 77, 95, 105,
LPe12002−E12, 40, 77, LPe1250−E11, 12, 40, 77;
QLogic: QLA2340−E−SP32, 35, QLE220−E−SP2,
12, 35, QLE2560−E−SP2, 12, 35, QLE2562−E−SP2,
12, 35
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31
220 HPQ Proliant: DL380 (G5), DL580 (G4) SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI, PCI
Express,
PCI−X
Emulex: LPe12000−E11, 12, 77, 95, 105,
LPe12002−E12, 40, 77, LPe1250−E11, 12, 40, 77;
QLogic: QLE2560−E−SP2, 12, 35,
QLE2562−E−SP2, 12, 35
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
221 Fujitsu Siemens Primergy TX200: S3, S4 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI, PCI
Express,
PCI−X
QLogic QLE2460−E−SP2, 12, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See55
222 Fujitsu Siemens Primergy TX200 S4 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI, PCI
Express,
PCI−X
QLogic QLE2460−E−SP2, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
223 Fujitsu Siemens Primergy RX800 S2 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI,
PCI−X Emulex LP1050−E11, 12, 40, 41 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31
224 Fujitsu Siemens Primergy RX800 S2 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI,
PCI−X Emulex LP1050−E11, 40, 41, 49 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y50, 51
225 Fujitsu Siemens Primergy RX800: S2, S3 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI,
PCI−X QLogic QLA2340−E−SP32, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31
226 IBM xSeries x3350 (4192,4193) SuSE
SLES
[32−Bit]
10: SP13,
4, 5, 6, 7, 8,
9, 10,
SP24, 5, 7,
8, 9, 33, 34
PCI
Express IBM: 42C2069 (LPe11000)11, 12, 18, 25, 26, 48,
42C2071 (LPe11002)11, 12, 18, 25, 26, 48 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31
227 IBM xSeries x3455 (7940) SuSE
SLES
[32−Bit]
10: SP13,
4, 5, 6, 7, 8,
9, 10,
SP24, 5, 7,
8, 9, 33, 34
PCI
Express IBM: 42C2069 (LPe11000)11, 12, 18, 25, 26, 48,
42C2071 (LPe11002)11, 12, 18, 25, 26, 48 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
228 IBM xSeries x3455 (7984) SuSE
SLES
[32−Bit]
10: SP13,
4, 5, 6, 7, 8,
9, 10,
SP24, 5, 7,
8, 9, 33, 34
PCI
Express IBM: 42C2069 (LPe11000)11, 12, 18, 25, 26, 48,
42C2071 (LPe11002)11, 12, 18, 25, 26, 48 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31, 50,
51
229 IBM xSeries x3655 (7943) SuSE
SLES
[32−Bit]
10: SP13,
4, 5, 6, 7, 8,
9, 10,
SP24, 5, 7,
8, 9, 33, 34
PCI
Express,
PCI−X
IBM: 42C2069 (LPe11000)11, 12, 17, 18, 25, 26, 48,
42C2071 (LPe11002)11, 12, 17, 18, 25, 26, 48 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See42
230 IBM xSeries x3655 (7985) SuSE
SLES
[32−Bit]
10: SP13,
4, 5, 6, 7, 8,
9, 10,
SP24, 5, 7,
8, 9, 33, 34
PCI
Express,
PCI−X
IBM: 42C2069 (LPe11000)11, 12, 17, 18, 25, 26, 48,
42C2071 (LPe11002)11, 12, 17, 18, 25, 26, 48 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31
231 IBM xSeries: x3550 (7978), x3650 (7979) SuSE
SLES
[32−Bit]
10: SP13,
4, 5, 6, 7, 8,
9, 10,
SP24, 5, 7,
8, 9, 33, 34
PCI
Express,
PCI−X
IBM: 42C2069 (LPe11000)11, 12, 17, 18, 25, 26, 48,
42C2071 (LPe11002)11, 12, 17, 18, 25, 26, 48,
42D0405 (LP11000)11, 12, 17, 18, 25, 26, 48,
42D0407 (LP11002)11, 12, 17, 18, 25, 26, 48
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31, 50,
51
CLARiiON AX150
03/04/2009 760 CLARiiON AX150