Red Hat RHEL [32−Bit]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
635 HPQ Proliant DL785 (G5);
IBM xSeries: x3455 (7940), x3850M2 (7141)29, x3950M2
(7141)29
Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express Emulex LPe12002−E3, 43,
45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See27, 28
636 Digital Henge INNO FS7000;
Fujitsu Siemens Primergy RX300 S4;
HCL Infiniti Global Line 4700 FC;
Intel S7000FC4UR;
LangChao NF520D2;
Lenovo SureServer R630 G7;
PowerLeader PR4850Q;
Samsung ZSS232;
Wipro NetPower Z4402
Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express Emulex LPe1250−E3, 17, 43,
45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y33 See28
637 Fujitsu Siemens Primergy RX300 S4 Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express Emulex LPe1250−E3, 43, 45;
QLogic QLE2460−E−SP1, 3,
21
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y33 See27, 28
638 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4, SR6850HW4;
Digital Henge INNO: HR−4850, HR−4850T, HR−6850,
HR−6850T;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: ZSS230−D, ZSS230−T;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express Emulex: LP101−E17, 43, 49,
LP1050−E17, 43, 49,
LP982−E43, 49, 57;
QLogic: QLA2340−E−SP20,
21, QLE2360−E−SP21, 25,
26
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
639 Digital Henge INNO FS7000;
HCL Infiniti Global Line 4700 FC;
Intel S7000FC4UR;
LangChao NF520D2;
Lenovo SureServer R630 G7;
PowerLeader PR4850Q;
Samsung ZSS232;
Wipro NetPower Z4402
Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express Emulex: LPe12000−E3, 17,
43, 45, LPe12002−E3, 17, 43,
45;
QLogic: QLE2360−E−SP21,
122, QLE2460−E−SP1, 3, 21,
QLE2560−E−SP1, 3, 21,
QLE2562−E−SP1, 3, 21
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y33 See28
640 Dell PowerEdge: 1950, 1950 III, 2900 III, 2950 III, 2970,
6800, 6850, R805, R900, R905 Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express Emulex: LPe12000−E3, 17,
43, 45, LPe12002−E3, 17, 43,
45;
QLogic: QLE2560−E−SP1,
3, 21, QLE2562−E−SP1, 3,
21
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See27
641 Fujitsu Siemens Primergy BX630 S2 Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express Fujitsu Siemens
BX600−FC42e3, 35, 42, 43,
78
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y79
642 HPQ Proliant: DL380 (G4), DL580 (G3)47, DL785 (G5),
ML370 (G4)47;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express HPQ A8002A/FC2142SR
(LPe1150)3, 12, 17, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
643 HPQ Proliant: BL260c G5 (quad core processor)7,
BL2x220c G5 (quad core processor)7, BL460c (dual core
processor)7, BL460c (quad core processor)7, BL465c
(dual core processor)7, BL465c G5 (quad core
processor)7, BL480c (dual core processor)7, BL480c
(quad core processor)7, BL495c G5 (quad core
processor), BL680c (G5)7, BL685c (dual core
processor)7, BL685c G5 (quad core processor)7
Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express HPQ Emulex LPe1105−HP
4Gb FC HBA for HP
c−Class Bladesystem
(403621−B21)12, 14, 43
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y79
644 HPQ Proliant: BL260c G5 (quad core processor)7,
BL2x220c G5 (quad core processor)7, BL460c (dual core
processor)7, BL460c (quad core processor)7, BL465c
(dual core processor)7, BL465c G5 (quad core
processor)7, BL480c (dual core processor)7, BL480c
(quad core processor)7, BL495c G5 (quad core
processor), BL680c (G5)7, BL685c (dual core
processor)7, BL685c G5 (quad core processor)7
Red Hat
RHEL
[32−Bit]
4.7
AS/ES4, 23
PCI
Express HPQ QLogic QMH2462
4Gb FC HBA for HP
c−Class Bladesystem
(403619−B21)21, 125
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 503 CLARiiON AX150