Red Hat RHEL [32−Bit]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
524 Sun Sun Fire: X2200−M2, X4150, X4450 Red Hat
RHEL
[32−Bit]
4.6
AS/ES4, 77
PCI
Express Sun: SG−XPCIE1FC−QF4
(QLE2460)3, 22, 76,
SG−XPCIE2FC−QF4
(QLE2462)3, 22, 76
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
525 Sun Sun Blade Server Module: X6220, X6250, X8440 Red Hat
RHEL
[32−Bit]
4.6
AS/ES4, 77
PCI
Express Sun:
SG−XPCIE2FC−EB4−Z
(LPem11002)3, 17, 37, 80,
SG−XPCIE2FC−QB4−Z
(QEM2462)3, 22, 76
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
526 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6800, 6850, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
Hewlett Packard Proliant ML350: (G4), (G4p);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[32−Bit]
4.6
AS/ES4, 77
PCI
Express,
PCI−X
Emulex LP101−E3, 17, 49, 80 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
527 HPQ Proliant: DL320 (G5), DL360 (G5), DL385 (G2),
DL385 (G5), DL585 (G2), DL585 (G5), ML350 (G5)47,
ML370 (G5)47, ML570 (G4)47;
Hewlett Packard Proliant ML350: (G4), (G4p)
Red Hat
RHEL
[32−Bit]
4.6
AS/ES4, 77
PCI
Express,
PCI−X
Emulex LP1050−E17, 49, 80;
HPQ AB429A/FC1143
(QLA2460)1, 3, 76
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
528 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6800, 6850, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL320 (G5), DL360 (G5), DL385 (G2),
DL385 (G5), DL585 (G2), DL585 (G5), ML350 (G5)47,
ML370 (G5)47, ML570 (G4)47;
IBM xSeries: x3550 (7978), x3650 (7979), x3755 (7163),
x3755 (8877);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[32−Bit]
4.6
AS/ES4, 77
PCI
Express,
PCI−X
Emulex LP1050−E3, 17, 49,
80 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
529 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
IBM: eServer 326m (Model 7969), xSeries x3655 (7985),
xSeries x3800/x260 (8866), xSeries x3850/x366 (8864);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[32−Bit]
4.6
AS/ES4, 77
PCI
Express,
PCI−X
Emulex LP1050Ex−E3, 17,
49, 80 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 489 CLARiiON AX150