VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
8 Dell PowerEdge: 1850, 1950 III,
2850, 2900, 2900 III, 2950, 2950
III, 2970, 6850, 6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2);
IBM xSeries: x336 (8837)71,
x3550 (7978), x3650 (7979),
x3800/x260 (8866), x3850/x366
(8864);
NEC Express 5800 140He
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
Emulex LP982−E2, 11, 23, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
9 Dell PowerEdge: 1950 III, 2900,
2900 III, 2950, 2950 III, 2970,
6950;
Fujitsu Siemens Primergy: RX200
S3, RX600 S3, TX600 S3;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G4)33
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
Emulex LPe1150−E1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
10 HPQ Proliant: DL385 (G2), DL585
(G2) VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
Emulex: LP11000−E1, 2, 11, 12, LP11002−E1, 2,
11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
11 HPQ Proliant: DL360 (G5), DL585
(G2), ML370 (G5)33, ML570
(G4)33
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
HPQ A8002A/FC2142SR (LPe1150)1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
12 HPQ Proliant DL585 (G2) VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
HPQ AB429A/FC1143 (QLA2460)12, 32, 49 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
13 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G4)33;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
HPQ AD167A/FC2143 (LP1150)1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
14 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G3)33, ML570 (G4)33;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
HPQ AE311A/FC1142SR (QLE2460)12, 32, 49 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
15 NEC Express 5800: 120Li,
120Rg−1, 120Ri−2, 140He VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
NEC N8190−120 (LP1050)2, 11, 35, 61 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
16 Fujitsu Siemens Primergy: RX200
S3, TX300 S3, TX600 S3;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G4)33;
IBM xSeries: x336 (8837)71, x346
(8840), x3550 (7978), x3650
(7979), x3755 (8877), x3800/x260
(8866), x3850/x366 (8864)
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
QLogic QLA2340−E−SP38, 39, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
17 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G4)33;
IBM xSeries: x3550 (7978), x3650
(7979), x3655 (7985), x3850/x366
(8864)
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
QLogic QLA2460−E−SP12, 32, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
18 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G3)33, ML570 (G4)33;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326m (Model 7969),
xSeries x3550 (7978), xSeries
x3650 (7979), xSeries x3655
(7985), xSeries x3755 (8877),
xSeries x3800/x260 (8866),
xSeries x3850/x366 (8864)
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI
Express,
PCI−X
QLogic QLE2460−E−SP12, 32, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
19 Fujitsu Siemens Primergy:
RX300, RX300 S2, RX600 S2,
TX300, TX300 S2
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI−X Emulex LP1050−E2, 11, 12, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150
03/04/2009 860 CLARiiON AX150