VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
228 Dell PowerEdge: 1850, 2850,
2900, 2950, 6950 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
QLogic: QLA2310F−E−SP29, 39, 81,
QLE2360−E−SP12, 29, 50, QLE2362−E−SP12, 29,
50
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
229 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850, 6950 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
QLogic: QLA2340−E−SP29, 39, 52,
QLA2342−E−SP29, 39, 52 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
230 Dell PowerEdge: 2900, 2950,
6950 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
QLogic: QLE2460−E−SP12, 29, 32, 59,
QLE2462−E−SP12, 29, 59 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
231 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
QLogic: QLE2460−E−SP12, 29, 32,
QLE2462−E−SP12, 29, 32 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
232 HPQ Proliant: DL380 (G5), DL580
(G5) VMware ESX Server
3i6, 7, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex: LP10000−E2, 23, 26, LP10000DC−E2,
23, 26, LP1050−E2, 23, 26, LP1050DC−E2, 23, 26,
LP1050Ex−E2, 12, 23, 26, LP8000−EMC26, 37, 42,
LP9002−E (LP9002L−E)2, 26, 37, LP9802−E2, 26,
35, 36, LP9802DC−E2, 23, 26, 34, LP982−E2, 23,
26, 34, LPe11002−E1, 2, 12, 26, LPe1150−E1, 2, 12,
26;
HPQ: A8002A/FC2142SR (LPe1150)1, 2, 12, 26,
A8003A/FC2242SR (LPe11002)1, 2, 12, 26,
AD167A/FC2143 (LP1150)1, 2, 12, 26,
AD168A/FC2243 (LP11002)1, 2, 12, 26,
AE311A/FC1142SR (QLE2460)12, 29, 32,
AE312A/FC1242SR (QLE2462)12, 29, 32,
FCA2214/281541−B21 (QLA2340)29, 38,
FCA2214DC/321835−B21 (QLA2342)29, 38;
QLogic: QLA2200F−EMC29, 41,
QLA2310F−E−SP29, 38, 39, QLA2340−E−SP29,
38, 39, QLA2342−E−SP29, 38, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
233 HPQ Proliant DL580 (G5) VMware ESX Server
3i6, 7, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex: LP11000−E1, 2, 12, 26, 31, LP11002−E1,
2, 12, 26, 31, LP1150−E1, 2, 12, 26, 31;
HPQ: AB429A/FC1143 (QLA2460)12, 29, 31, 32,
AE369A/FC1243 (QLA2462)12, 29, 31, 32;
QLogic: QLA2460−E−SP12, 29, 31, 32,
QLA2462−E−SP12, 29, 31, 32
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
234 HPQ Proliant DL380 (G5) VMware ESX Server
3i6, 7, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex: LP11000−E1, 2, 12, 26, LP11002−E1, 2,
12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
235 HPQ Proliant: DL380 (G5), DL580
(G5) VMware ESX Server
3i6, 7, 9, 10, 28 PCI, PCI
Express,
PCI−X
QLogic: QLE2460−E−SP12, 29, 32,
QLE2462−E−SP12, 29, 32, QLE2560−E−SP12, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
236 Fujitsu Siemens Primergy BX630:
(2−way), (4−way) VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI Emulex LP1050−E2, 11, 12, 23;
Fujitsu Siemens BX600−FC22Q12, 49, 52, 72 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
237 Fujitsu Siemens Primergy BX630:
(2−way), (4−way);
HPQ Proliant DL380 (G3)
VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI Emulex LP1050−E2, 11, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
238 HPQ Proliant DL380 (G3) VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI Emulex LP982−E2, 11, 23, 34;
QLogic QLA2340−E−SP38, 39, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
239 Fujitsu Siemens Primergy
BX66073 VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI Fujitsu Siemens BX600−FC22Q12, 43, 52, 72 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
240 Dell PowerEdge: 1950, 6850;
Fujitsu Siemens Primergy RX300
S3;
IBM xSeries x3455 (7984)
VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express Emulex LP1050Ex−E2, 11, 12, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
241 Dell PowerEdge 1950 VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express QLogic QLA2340−E−SP39, 43, 52 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
242 Dell PowerEdge 6850 VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express QLogic QLE2360−E−SP12, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
243 Dell PowerEdge 1950;
IBM xSeries x3455 (7984) VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express QLogic QLE2360−E−SP12, 43, 50 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
244 Dell PowerEdge 6850 VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Dell 2362M43, 66, 67 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
245 HPQ Proliant: ML370 (G5)33,
ML570 (G4)33;
IBM xSeries x3755 (8877)
VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Emulex LP1050−E2, 11, 12, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
246 HPQ Proliant: DL360 (G5), DL385
(G2), ML370 (G5)33, ML570
(G4)33
VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
HPQ AB429A/FC1143 (QLA2460)12, 32, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150
03/04/2009 875 CLARiiON AX150