SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
96 Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2 SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI
Express,
PCI−X
Sun: SG−XPCI1FC−QF4
(QLA2460)27, 65,
SG−XPCI2FC−QF4
(QLA2462)27, 65,
SG−XPCIE1FC−QF4
(QLE2460)27, 65,
SG−XPCIE2FC−QF4
(QLE2462)27, 65
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
97 Dell PowerEdge 1855 SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Dell: 2342M27, 36,
LPe1105−M1, 37, 38, 50,
64, 68, QME24621, 13, 27
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
98 Dell PowerEdge: 6800, 6850;
Hewlett Packard Proliant DL360: (G4), (G4p);
IBM xSeries: x336 (8837)78, x346 (8840), x3800/x260
(8865)82, 83, x3850/x366 (8863)82, 83, x3950/x3950E/x460
(8872, 8874)82, 83
SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex LP101−E1, 10, 37,
38, 55, 68 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
99 Fujitsu Siemens Primergy TX600 S2 SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex LP1050−E1, 10,
37, 38, 55, 68 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
100 Fujitsu Siemens Primergy TX600 S2 SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex LP1050−E10, 37,
38, 55, 59, 68 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y48, 49
101 Fujitsu Siemens Primergy RX600 S2 SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex LP1050Ex−E1,
10, 37, 38, 55, 68 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
102 HPQ Proliant: DL140 (G3), DL145 (G2);
Hewlett Packard Proliant DL360: (G4), (G4p)
SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex LP11000−E1, 10,
11, 37, 38, 68;
HPQ AB429A/FC1143
(QLA2460)1, 13, 27;
QLogic:
QLA2460−E−SP1, 13, 27,
QLA2462−E−SP1, 13, 27
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
103 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex LPe1150−E1, 10,
11, 37, 38;
QLogic
QLE2460−E−SP13, 27
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
104 Dell PowerEdge: 6800, 6850;
IBM xSeries: x336 (8837)78, x346 (8840), x3800/x260
(8865)82, 83, x3850/x366 (8863)82, 83, x3950/x3950E/x460
(8872, 8874)82, 83
SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex: LP1050−E1, 10,
37, 38, 55, 68, LP982−E1,
38, 54, 55, 68, 116
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
105 Hewlett Packard Proliant DL360: (G4), (G4p) SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex: LP1050−E10, 37,
38, 55, 68, LP982−E38, 54,
55, 68, 116
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
106 HPQ Proliant: DL140 (G3), DL145 (G2) SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex: LP1150−E1, 10,
11, 37, 38, 68,
LPe11000−E1, 10, 11, 37,
38;
HPQ A8002A/FC2142SR
(LPe1150)1, 10, 11, 37, 38,
68
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
107 Fujitsu Siemens Primergy RX330;
HPQ Proliant: DL140 (G3), DL145 (G2) SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X Emulex: LPe11002−E1,
10, 11, 37, 38,
LPe1150−E1, 10, 11, 37,
38, LPe1150−E1, 10, 11,
37, 38, 68;
QLogic
QLE2460−E−SP13, 27
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
108 Dell PowerEdge: 1950, 6800, 6850 SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X QLogic
QLA2340−E−SP27 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
109 Fujitsu Siemens Primergy: RX330, RX600 S2, TX600 S2;
HPQ Proliant: DL140 (G3), DL145 (G2);
Hewlett Packard Proliant DL360: (G4), (G4p);
IBM xSeries: x336 (8837)78, x346 (8840),
x3950/x3950E/x460 (8878, 8879)
SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X QLogic
QLA2340−E−SP27, 36 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
110 HPQ Proliant: DL140 (G3), DL145 (G2);
IBM xSeries x3950/x3950E/x460 (8878, 8879)
SuSE
SLES
[x86_64]
10 SP15, 6,
7, 20, 23, 24,
25, 26
PCI−X QLogic
QLA2460−E−SP13, 27 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 792 CLARiiON AX150