Asianux AX [x86_64]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
58 HPQ Proliant DL380 (G5) Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI, PCI
Express,
PCI−X
Emulex: LP11000−E6, 8, 9, 23, LP11002−E6,
8, 9, 23, LP1150−E6, 8, 9, 23;
HPQ: AB429A/FC1143 (QLA2460)6, 17, 49,
AE369A/FC1243 (QLA2462)6, 17, 49;
QLogic QLA2462−E−SP6, 17, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
59 HPQ Proliant DL380: (G4), (G5) Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI, PCI
Express,
PCI−X
QLogic QLA2460−E−SP6, 17, 49 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
60 HPQ Proliant DL580 (G3)51 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI, PCI
Express,
PCI−X
QLogic QLE220−E−SP6, 17, 45, 60 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
61 Dell PowerEdge: 1800, 2800 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI, PCI
Express,
PCI−X
QLogic QLE220−E−SP6, 44, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
62 HPQ Proliant: DL145, DL380, DL380 (G2), DL380
(G3), DL380 (G4), DL385, DL580 (G2)51, DL580
(G3)51, DL585, ML370 (G3)51, ML370 (G4)51
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI,
PCI−X Emulex: LP101−E6, 8, 23, 42, LP1050−E8, 23,
42, LP982−E23, 50;
QLogic: QLA200−E−SP6, 38, 49,
QLA210−E−SP6, 38, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
63 Dell PowerEdge: 1800, 1850, 2800, 2850 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI,
PCI−X Emulex: LP1050−E6, 8, 23, 42, LP982−E6, 23,
50;
QLogic QLA2340−E−SP6, 41, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
64 HPQ Proliant: DL380 (G4), DL385, DL585, ML370
(G4)51 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI,
PCI−X HPQ: AB429A/FC1143 (QLA2460)6, 17, 49,
AE369A/FC1243 (QLA2462)6, 17, 49;
QLogic: QLA2460−E−SP6, 17, 49,
QLA2462−E−SP6, 17, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
65 HPQ Proliant: DL145, DL380 (G4), DL385, DL580
(G2)51, DL580 (G3)51, DL585, ML370 (G3)51,
ML370 (G4)51
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI,
PCI−X QLogic QLA2340−E−SP41, 49 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
66 HPQ Proliant: DL145, DL380, DL380 (G2), DL380
(G3), DL380 (G4), DL580 (G2)51, DL580 (G3)51,
ML370 (G3)51, ML370 (G4)51
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI,
PCI−X QLogic QLE220−E−SP6, 17, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
67 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500,
255052, 4300, 4350, 4400, 6100, 6300, 6350, 6400,
6450, 8450;
HPQ Proliant: DL320, DL360, DL360 (G2), DL380,
DL380 (G2), DL380 (G3), DL580 (G2)51, DL58051,
ML350 (G2)51, ML350 (G3)51, ML35051, ML370
(G2)51, ML37051, ML530 (G2)51, ML530 (G3)51,
ML53051, ML57051, ML75051
Asianux
AX
[x86_64]
2.0 SP3
PCI Emulex LP101−E6, 8, 42, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y10
68 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500,
255052, 4300, 4350, 4400, 6100, 6300, 6350, 6400,
6450, 8450
Asianux
AX
[x86_64]
2.0 SP3
PCI Emulex LP1050−E6, 8, 42, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y10
69 HPQ Proliant: DL320, DL360, DL360 (G2),
DL58051, ML350 (G2)51, ML350 (G3)51, ML35051,
ML370 (G2)51, ML37051, ML530 (G2)51, ML530
(G3)51, ML53051, ML57051, ML75051
Asianux
AX
[x86_64]
2.0 SP3
PCI Emulex LP1050−E8, 42, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y10
70 Dell PowerEdge: 1800, 2800, 2850, 6800, 6850 Asianux
AX
[x86_64]
2.0 SP3
PCI
Express Emulex LP101−E6, 8, 42, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y10
71 Dell PowerEdge: 1800, 2800, 2850 Asianux
AX
[x86_64]
2.0 SP3
PCI
Express Emulex LP1050−E6, 8, 42, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y10
72 HPQ Proliant: DL380 (G4), DL580 (G3)51, ML370
(G4)51;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Asianux
AX
[x86_64]
2.0 SP3
PCI
Express Emulex LPe111−E6, 8, 9, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y10
73 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850,
6800, 6850;
HPQ Proliant: DL380 (G4), DL580 (G3)51, ML370
(G4)51;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Asianux
AX
[x86_64]
2.0 SP3
PCI
Express Emulex LPe1150−E6, 8, 9, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y10
74 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850,
6800, 6850 Asianux
AX
[x86_64]
2.0 SP3
PCI
Express Emulex: LP1050Ex−E6, 8, 42, 43, LPe111−E6,
8, 43, 47, 48 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y10
CLARiiON AX150
03/04/2009 45 CLARiiON AX150