SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
185 Dell PowerEdge: 1800, 1850, 1950, 1950 III, 2800, 2850,
2900 III, 2950 III, 2970, 6800, 6850, R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
IBM xSeries: x3350 (4192,4193), x3455 (7940), x3455
(7984), x3850M2 (7233, 7234), x3950M2 (7233, 7234);
Sun Sun Fire: X2200−M2, X4140, X4150, X4240, X4440,
X4450
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic
QLE2460−E−SP13, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
186 Fujitsu Siemens Primergy RX300 S3;
IBM xSeries: x3850M2 (7141)67, x3950M2 (7141)67 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic
QLE2460−E−SP13, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
187 HPQ Proliant DL785 (G5) SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic
QLE2460−E−SP13, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See44
188 Sun Sun Fire X4250 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic
QLE2460−E−SP13, 29;
Sun:
SG−XPCIE1FC−QF4
(QLE2460)29, 65,
SG−XPCIE2FC−QF4
(QLE2462)29, 65
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14, 48,
49
189 Dell PowerEdge: 1800, 1850, 1950, 1950 III, 2800, 2850,
2900 III, 2950 III, 2970, 6800, 6850, R805, R900, R905 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic
QLE2462−E−SP1, 13, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
190 Dell PowerEdge: R805, R900, R905;
HPQ Proliant DL785 (G5)
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic
QLE2462−E−SP1, 13, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See22
191 Dell PowerEdge: 1950, 1950 III, 2900 III, 2950 III, 2970,
6800, 6850, R805, R900, R905;
IBM xSeries x3455 (7940)
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic:
QLE2560−E−SP1, 13, 29,
QLE2562−E−SP1, 13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
192 IBM xSeries x3850M2 (7141)67 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic:
QLE2560−E−SP1, 13, 29,
QLE2562−E−SP1, 13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14, 58 See22
193 IBM xSeries x3950M2 (7141)67 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic:
QLE2560−E−SP1, 13, 29,
QLE2562−E−SP1, 13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14 See22
194 IBM xSeries: x3350 (4192,4193), x3850M2 (7233, 7234),
x3950M2 (7233, 7234) SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express QLogic:
QLE2560−E−SP1, 13, 29,
QLE2562−E−SP1, 13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y58 See22
195 Sun Sun Fire: X4140, X4240, X4440 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express Sun:
SG−XPCI1FC−EM4−Z
(LP11000)1, 10, 11, 34,
SG−XPCI1FC−QF4
(QLA2460)29, 65,
SG−XPCI2FC−EM4−Z
(LP11002)1, 10, 11, 34,
SG−XPCI2FC−QF4
(QLA2462)29, 65,
SG−XPCIE1FC−EM4
(LPE11000)10, 11, 34,
SG−XPCIE2FC−EM4
(LPE11002)10, 34, 50, 51
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
196 Sun Sun Fire: X2200−M2, X4150, X4250, X4450 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express Sun:
SG−XPCI1FC−EM4−Z
(LP11000)1, 10, 11, 34,
SG−XPCIE1FC−EM4
(LPE11000)10, 11, 34,
SG−XPCIE2FC−EM4
(LPE11002)10, 34, 50, 51
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14, 48,
49
197 Sun Sun Fire: X2200−M2, X4140, X4150, X4240 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express Sun:
SG−XPCIE1FC−EM8−Z
(LPe12000)1, 10, 41, 81,
SG−XPCIE1FC−QF8−Z
(QLE2560)1, 13, 29,
SG−XPCIE2FC−EM8−Z
(LPe12002)1, 10, 34, 41,
SG−XPCIE2FC−QF8−Z
(QLE2562)1, 13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y58 See22, 44
198 Sun Sun Fire: X2200−M2, X4140, X4150, X4240, X4440,
X4450 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express Sun:
SG−XPCIE1FC−QF4
(QLE2460)29, 65,
SG−XPCIE2FC−QF4
(QLE2462)29, 65
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 798 CLARiiON AX150