Microsoft Windows 2008 [x64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
232 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4,
SR6850HW4;
Digital Henge INNO: HR−4850, HR−4850T,
HR−6850, HR−6850T;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R630 G5, R650, R650 G5,
T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: ZSS230−D, ZSS230−T;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI−X Emulex: LP10000−E2, 4, 5,
18, 39, LP10000DC−E2, 4, 5,
18, 39, LP1050−E2, 4, 5, 18,
39, LP1050DC−E2, 4, 5, 18,
39, LP11000−E1, 2, 3, 4, 5,
18, LP11002−E1, 2, 3, 4, 5,
18, LP1150−E1, 2, 3, 4, 5, 18,
LP9802−E4, 5, 18, 39, 49,
LP9802DC−E4, 5, 18, 39, 49,
LP982−E4, 5, 18, 39, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9 See6
233 Dell PowerEdge: 2800, 2850, 6800, 6850 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI−X Emulex: LP10000−E2, 4, 5,
18, 39, LP10000DC−E2, 4, 5,
18, 39, LP9802−E4, 5, 18, 39,
49, LP9802DC−E4, 5, 18, 39,
49, LP982−E4, 5, 18, 39, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
234 IBM xSeries x3950/x3950E/x460 (8878, 8879) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI−X Emulex: LP10000−E2, 4, 5,
39, LP10000DC−E2, 4, 5, 39,
LP1050−E2, 4, 5, 39,
LP1050DC−E2, 4, 5, 39,
LP9802−E4, 5, 39, 49,
LP9802DC−E4, 5, 39, 49,
LP982−E4, 5, 39, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9 See6
235 Dell PowerEdge: 2800, 2850, 6800, 6850;
HPQ Proliant ML570 (G3)31;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI−X Emulex: LP1050−E2, 4, 5,
18, 39, LP1050DC−E2, 4, 5,
18, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
236 HPQ Proliant ML570 (G3)31;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI−X Emulex: LP11000−E1, 2, 3,
18, 21, 23, LP11002−E1, 2, 3,
18, 21, 23
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
237 IBM xSeries x3950/x3950E/x460 (8878, 8879) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI−X Emulex: LP11000−E1, 2, 3,
4, 5, LP11002−E1, 2, 3, 4, 5;
IBM: 42D0405 (LP11000)1,
2, 3, 4, 23, 42D0407
(LP11002)2, 3, 4, 23, 43
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
238 IBM xSeries: x3650 (7979), x3655 (7985) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI−X Emulex: LPe12000−E2, 3, 4,
5, 18, 25, LPe12002−E2, 3, 4,
5, 18, 25;
IBM: 42D0485
(LPe12000)2, 3, 21, 23, 25, 27,
42D0494 (LPe12002)2, 3,
21, 23, 25, 26, 42D0501
(QLE2560)3, 10, 12, 29,
42D0510 (QLE2562)3, 10,
12, 28
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
239 Fujitsu Siemens Primergy RX330 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI−X Emulex: LPe12002−E3, 4, 5,
25, 30, LPe1250−E3, 4, 5, 25,
30
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See6
240 HPQ Proliant ML570 (G3)31;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI−X HPQ: AD167A/FC2143
(LP1150)1, 2, 3, 18, 21, 23,
AD168A/FC2243
(LP11002)1, 2, 3, 18, 21, 23,
FCA2214/281541−B21
(QLA2340)10, 13, 18, 19,
FCA2214DC/321835−B21
(QLA2342)10, 13, 18, 19
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 232 CLARiiON AX150