Red Hat RHEL [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
617 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI−X QLogic QLE2460−E−SP3,
20, 101 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See21
618 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI−X QLogic QLE2462−E−SP3,
20, 101 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
619 Fujitsu Siemens Primergy: RX200 S2, RX300 S2, RX330,
RX600 S2, TX200 S2, TX300 S2, TX600 S2 Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI−X QLogic: QLA2340−E−SP3,
24, 101, QLA2340−E−SP24,
101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y61
620 Acer Altos R710;
Anders & Rodewyk Ariane: 145, 245;
Aquarius AquaServer TD322;
BGM Elitas: SR510, SR710;
Compusys ProManaged: SR1400JR2, SR2400JR2;
Digital Henge Revo: JS1400, JS2400;
Gateway: E−9415R, E−9515R;
Intel: SR1400/SE7520JR2, SR2400/SE7520JR2;
MPC NetFRAME: 1720, 2720;
MaxData Platinum: 1500 IR M5, 2200 IR M5;
Nanobay: JR1400, JR2400;
Ockam OS−7000;
PowerLeader: PR1700, PR1700 G2, PR2700, PR2700
G2;
R−Style MARSHALL: NP281r, NP282r;
Samsung ZSS150;
Verari RM2205;
Wortmann TERRA AQUA: 6200, 6300, 6500
Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI−X106 Emulex: LP1050−E3, 12, 13,
15, LP982−E3, 13, 15, 16;
QLogic QLA2340−E−SP3,
24, 101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
621 Dell PowerEdge 1955 Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI, PCI
Express,
PCI−X
Dell: LPe1105−M3, 13, 37,
64, QME24623, 20, 101 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
622 HPQ Proliant: DL380 (G5), DL580 (G5) Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI, PCI
Express,
PCI−X
Emulex LP1050−E12, 13, 15;
HPQ AE311A/FC1142SR
(QLE2460)3, 20, 101;
QLogic QLA2340−E−SP24,
101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
623 HPQ Proliant DL380: (G4), (G5);
HPQ Proliant DL580: (G4), (G5)
Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI, PCI
Express,
PCI−X
Emulex LP1150−E3, 12, 13,
14 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
624 HPQ Proliant: DL380 (G5), DL580 (G4) Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI, PCI
Express,
PCI−X
Emulex LPe111−E3, 12, 13,
14;
QLogic QLE2460−E−SP3,
20, 101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
625 Fujitsu Siemens Primergy TX200 S3 Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI, PCI
Express,
PCI−X
Emulex LPe1150−E3, 12, 13,
14;
QLogic: QLA2340−E−SP3,
24, 101, QLA2340−E−SP24,
101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y61
626 HPQ Proliant DL580 (G5) Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI, PCI
Express,
PCI−X
Emulex:
LP10000ExDC−E3, 12, 13,
15, LP1050−E3, 12, 13, 15,
LP1050Ex−E3, 12, 13, 15;
QLogic QLA2340−E−SP3,
24, 101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
627 HPQ Proliant DL380 (G5) Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI, PCI
Express,
PCI−X
Emulex: LP101−E3, 12, 13,
15, LP982−E13, 15, 16 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
628 HPQ Proliant: DL380 (G5), DL580 (G4), DL580 (G5) Red Hat
RHEL
[x86_64]
4.7
AS/ES9, 11
PCI, PCI
Express,
PCI−X
Emulex: LP11000−E3, 12,
13, 14, LP11002−E3, 12, 13,
14, LPe1150−E3, 12, 13, 14;
HPQ: A8002A/FC2142SR
(LPe1150)3, 12, 13, 14,
AB429A/FC1143
(QLA2460)3, 20, 101,
AE312A/FC1242SR
(QLE2462)3, 20, 101;
QLogic QLA2462−E−SP3,
20, 101
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 684 CLARiiON AX150