Asianux AX [32−Bit]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
133 IBM xSeries x3455: (7940), (7984) Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express QLogic: QLE2360−E−SP8, 9, 23,
QLE2362−E−SP8, 9, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12, 17 See15
134 Sun Sun Fire: X2200−M2, X4150, X4450 Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express Sun: SG−XPCI1FC−EM4−Z (LP11000)6,
9, 14, 16, SG−XPCIE1FC−EM4
(LPE11000)6, 9, 14, 16,
SG−XPCIE2FC−EM4 (LPE11002)6, 9, 16,
26, 44
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12 See15
135 Sun Sun Blade Server Module: X6220, X6250, X8440 Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express Sun: SG−XPCIE2FC−EB4−Z
(LPem11002)6, 9, 16, 26,
SG−XPCIE2FC−QB4−Z (QEM2462)8, 9,
27
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12 See15
136 HPQ Proliant: DL320 (G5), DL360 (G5), DL365,
DL385 (G2), DL585 (G2), DL585 (G5), ML350 (G5)25,
ML370 (G5)25, ML570 (G3)25, ML570 (G4)25;
IBM xSeries: x3550 (7978), x3650 (7979), x3655
(7943), x3655 (7985), x3755 (8877), x3800/x260
(8866), x3850/x366 (8864);
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
Emulex LP11000−E6, 9, 14, 16 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12 See15
137 HPQ Proliant: DL320 (G5), DL360 (G5), DL365,
DL385 (G2), DL585 (G2), DL585 (G5), ML350 (G5)25,
ML370 (G5)25, ML570 (G4)25
Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
Emulex LP1150−E6, 9, 14, 16;
HPQ: AB429A/FC1143 (QLA2460)7, 8, 9,
AE311A/FC1142SR (QLE2460)7, 8, 9,
AE312A/FC1242SR (QLE2462)7, 8, 9,
AE369A/FC1243 (QLA2462)7, 8, 9
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12 See15
138 Dell PowerEdge: 1900, 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950 Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
Emulex LPe11002−E6, 9, 14, 16 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12, 62 See15
139 HPQ Proliant DL320 (G5) Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
Emulex LPe1150−E6, 9, 14, 16 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17
140 HPQ Proliant: DL320 (G5), DL360 (G5), DL365,
DL385 (G2), DL585 (G2), DL585 (G5), ML350 (G5)25,
ML370 (G5)25, ML570 (G3)25, ML570 (G4)25
Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
Emulex: LP1050−E6, 16, 28, 29,
LP1050−E6, 9, 16, 28 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12 See15
141 HPQ Proliant DL 585 (G5) Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
Emulex: LP1050−E6, 16, 28, 29,
LP1050−E6, 9, 16, 28, LP11000−E6, 9, 14,
16, LP1150−E6, 9, 14, 16, LPe11000−E6, 9,
14, 16, LPe11002−E6, 9, 14, 16;
HPQ: AB429A/FC1143 (QLA2460)7, 8, 9,
AE311A/FC1142SR (QLE2460)7, 8, 9,
AE312A/FC1242SR (QLE2462)7, 8, 9,
AE369A/FC1243 (QLA2462)7, 8, 9,
FCA2214/281541−B21 (QLA2340)8, 21,
FCA2214DC/321835−B21 (QLA2342)8,
21;
QLogic: QLA2340−E−SP8, 9, 18,
QLA2342−E−SP8, 9, 18, QLA2460−E−SP8,
9, 22, QLA2462−E−SP8, 9, 22
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See15
142 HPQ Proliant: DL320 (G5), DL360 (G5), DL365,
DL385 (G2), DL585 (G2), DL585 (G5), ML350 (G5)25,
ML370 (G5)25, ML570 (G3)25, ML570 (G4)25;
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
Emulex: LPe11000−E6, 9, 14, 16,
LPe11002−E6, 9, 14, 16 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12 See15
143 HPQ Proliant: DL320 (G5), DL585 (G2), DL585 (G5) Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
HPQ: FCA2214/281541−B21 (QLA2340)8,
21, FCA2214DC/321835−B21
(QLA2342)8, 21
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12 See15
144 IBM xSeries x3650 (7979) Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
IBM: 42C2069 (LPe11000)6, 9, 14, 16,
42C2071 (LPe11002)6, 9, 14, 16;
QLogic: QLE2360−E−SP8, 9, 23,
QLE2362−E−SP8, 9, 23, QLE2460−E−SP8,
9, 22, QLE2462−E−SP8, 9, 22
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y12, 17 See15
145 NEC Express 5800 120Rj−2 Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
NEC N8190−120: (LP1050)1, 6, 16, 39,
(LP1050)6, 16, 28, 39;
NEC N8190−127: (LPe1150)6, 14, 16, 38,
(LPe1150)6, 16, 37, 38;
NEC N8190−131 (LPe11002)6, 14, 16
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
146 NEC Express 5800 120Rj−2 Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
NEC: N8190−120 (LP1050)16, 39, 40, 52,
N8190−127 (LPe1150)16, 38, 52, 54,
N8190−131 (LPe11002)16, 52, 54
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y53
147 HPQ Proliant: DL320 (G5), DL360 (G5), DL385 (G2),
ML350 (G5)25, ML370 (G5)25, ML570 (G4)25;
IBM xSeries: x3550 (7978), x3650 (7979), x3655
(7985), x3755 (8877), x3800/x260 (8866), x3850/x366
(8864)
Asianux
AX
[32−Bit]
3.0 SP13,
10, 11
PCI
Express,
PCI−X
QLogic QLA2340−E−SP8, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 20 CLARiiON AX150