SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
464 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL320 (G5), DL360 (G5), ML350 (G5)40,
ML370 (G5)40, ML570 (G4)40;
IBM xSeries: x3550 (7978), x3650 (7979);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI
Express,
PCI−X
Emulex LP1050−E1, 9, 10,
53 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
465 HPQ Proliant: DL365, DL385 (G2), DL585 (G2);
IBM xSeries x3755 (8877)
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI
Express,
PCI−X
Emulex LP1050−E1, 9, 10,
53 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
466 Fujitsu Siemens Primergy BX620 S4;
HPQ Proliant: DL365, DL385 (G2), DL585 (G2) SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI
Express,
PCI−X
Emulex LP1050−E9, 10,
53 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
467 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, ML350
(G5)40, ML370 (G5)40, ML570 (G4)40;
Hewlett Packard Proliant ML350: (G4), (G4p)
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI
Express,
PCI−X
Emulex LP1050−E9, 10;
HPQ: AB429A/FC1143
(QLA2460)1, 13, 56,
AE369A/FC1243
(QLA2462)1, 13, 56
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
468 Fujitsu Siemens Primergy RX220;
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7985),
x3755 (8877), x3800/x260 (8866), x3850/x366 (8864)
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI
Express,
PCI−X
Emulex LP1050Ex−E1,
10, 53, 55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
469 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)40, ML370 (G5)40, ML570
(G4)40
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI
Express,
PCI−X
Emulex LP11000−E1, 10,
11, 53 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
470 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)40, ML370 (G5)40, ML570
(G4)40;
IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877)
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI
Express,
PCI−X
Emulex LP1150−E1, 10,
11, 53 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
471 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
IBM xSeries: x3550 (7978), x3650 (7979);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI
Express,
PCI−X
Emulex LP982−E1, 53, 54,
55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
472 IBM xSeries x3755 (8877) SuSE
SLES
[x86_64] 9
SP35, 6, 7,
52
PCI
Express,
PCI−X
Emulex LP982−E1, 53, 54,
55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
CLARiiON AX150
03/04/2009 830 CLARiiON AX150