VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
428 Dell PowerEdge: R805, R900,
R905;
HPQ Proliant DL785 (G5)
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express QLogic: QLE2460−E−SP12, 29, 32, 59,
QLE2462−E−SP12, 29, 59 FC−SW EMC
CLARiiON
AX150
Y
429 Dell PowerEdge: 1950 III, 2900
III, 2950 III, 2970 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LPe11002−E1, 2, 12, 26, LPe1150−E1, 2,
12, 26 FC−SW EMC
CLARiiON
AX150
Y13, 14
430 Dell PowerEdge: 1950 III, 2900,
2900 III, 2950, 2950 III, 2970,
6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LPe12000−E12, 26, 78, LPe12002−E12,
26, 78 FC−SW EMC
CLARiiON
AX150
Y13, 14
431 IBM BladeCenter HS12 (Model
8014,8028) VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
IBM QLogic: 4gb FC Exp Card (CFFv,
41Y8527)12, 29, Ethernet and 4gb FC Exp Card
(CFFh, 39Y9306)12, 29, 87
FC−SW EMC
CLARiiON
AX150
Y13, 14
432 Dell PowerEdge: 1950 III, 2900,
2900 III, 2950, 2950 III, 2970,
6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33
VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
QLogic QLE2562−E−SP12, 29 FC−SW EMC
CLARiiON
AX150
Y
433 Dell PowerEdge: 1950 III, 2900
III, 2950 III, 2970 VMware ESX Server
3i6, 7, 9, 10, 28 PCI
Express,
PCI−X
QLogic: QLE2460−E−SP12, 29, 32, 59,
QLE2462−E−SP12, 29, 59 FC−SW EMC
CLARiiON
AX150
Y
434 IBM BladeCenter HS21 (Model
8853)104 VMware ESX Server
3i6, 7, 9, 10, 28 PCI−X IBM HS20 FC Exp Card: (13N2203/26R0836)12,
29, 75, (48P7061/26R0836)12, 29 FC−SW EMC
CLARiiON
AX150
Y13, 14
435 IBM BladeCenter HS21: (Model
8853)104, XM (Model 7995)107;
IBM BladeCenter: LS21 (Model
7971)104, LS41 (Model 7972)104
VMware ESX Server
3i6, 7, 9, 10, 28 PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card
(39Y9186)1, 12, 26, 77, HS20 4GB SFF FC Exp
Card (26R0890/26R0893)12, 29, 76
FC−SW EMC
CLARiiON
AX150
Y13, 14
436 IBM BladeCenter: HS21 XM
(Model 7995)107, LS21 (Model
7971)104, LS41 (Model 7972)104
VMware ESX Server
3i6, 7, 9, 10, 28 PCI−X IBM: HS20 FC Exp Card (26K4841/26K4859)12,
29, 68, 69, QLogic 4gb FC Exp Card (CFFv,
41Y8527)12, 29, QLogic Ethernet and 4gb FC
Exp Card (CFFh, 39Y9306)12, 29, 87
FC−SW EMC
CLARiiON
AX150
Y13, 14
437 HPQ Proliant: DL380 (G5), DL580
(G5) VMware ESX Server
3i6, 7, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex: LPe12000−E12, 26, 78, LPe12002−E12,
26, 78 FC−SW EMC
CLARiiON
AX150
Y13, 14
438 HPQ Proliant: DL380 (G5), DL580
(G5) VMware ESX Server
3i6, 7, 9, 10, 28 PCI, PCI
Express,
PCI−X
QLogic QLE2562−E−SP12, 29 FC−SW EMC
CLARiiON
AX150
Y
439 Dell PowerEdge: 1850, 2850,
6850 VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17
PCI
Express,
PCI−X
QLogic QLA2340−E−SP21, 52 FC−SW EMC
CLARiiON
AX150
Y13, 14
440 Dell PowerEdge: 1850, 2850 VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17
PCI
Express,
PCI−X
QLogic QLE2360−E−SP12, 21, 50, 51 FC−SW EMC
CLARiiON
AX150
Y13, 14
441 HPQ Proliant BL20p (G3) VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17
PCI−X20 HPQ HP QLogic−based Fibre Channel
Mezzanine HBA for BL20p G3/BL20p G4
361426−B2121, 22
FC−SW EMC
CLARiiON
AX150
Y13, 14
442 Fujitsu Siemens Primergy BX620:
S2F73, S273;
Fujitsu Siemens Primergy:
BX62073, BX630 (2−way)109,
BX66073
VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17,
2.5.44, 5, 6, 7, 9, 15, 16,
17, 18, 19, 74, 2.5.54, 5, 6,
7, 9, 15, 16, 17, 18, 19
PCI Fujitsu Siemens BX600−FC22Q12, 21, 52, 72 FC−SW EMC
CLARiiON
AX150
Y13, 14
443 HPQ Proliant: DL360, DL360
(G2), DL380 (G3), DL58033;
IBM xSeries: x330, x335;
NEC Express 5800 140Hd
VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17,
2.5.44, 5, 6, 7, 9, 15, 16,
17, 18, 19, 74, 2.5.54, 5, 6,
7, 9, 15, 16, 17, 18, 19
PCI QLogic QLA2340−E−SP21, 38 FC−SW EMC
CLARiiON
AX150
Y13, 14
444 Dell PowerEdge: 1550, 2550110,
6450 VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17,
2.5.44, 5, 6, 7, 9, 15, 16,
17, 18, 19, 74, 2.5.54, 5, 6,
7, 9, 15, 16, 17, 18, 19
PCI QLogic QLA2340−E−SP21, 52 FC−SW EMC
CLARiiON
AX150
Y13, 14
445 Dell PowerEdge 6850 VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17,
2.5.44, 5, 6, 7, 9, 15, 16,
17, 18, 19, 74, 2.5.54, 5, 6,
7, 9, 15, 16, 17, 18, 19
PCI
Express QLogic QLE2360−E−SP12, 21, 51 FC−SW EMC
CLARiiON
AX150
Y13, 14
446 Dell PowerEdge 6850 VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17,
2.5.44, 5, 6, 7, 9, 15, 16,
17, 18, 19, 74, 2.5.54, 5, 6,
7, 9, 15, 16, 17, 18, 19
PCI
Express,
PCI−X
Dell 2362M21, 66, 67 FC−SW EMC
CLARiiON
AX150
Y13, 14
447 IBM xSeries: x336 (8837)71, x346
(8840) VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17,
2.5.44, 5, 6, 7, 9, 15, 16,
17, 18, 19, 74, 2.5.54, 5, 6,
7, 9, 15, 16, 17, 18, 19
PCI
Express,
PCI−X
QLogic QLA2340−E−SP21, 38 FC−SW EMC
CLARiiON
AX150
Y13, 14
448 Dell PowerEdge 1855 VMware ESX Server:
2.5.24, 6, 7, 9, 15, 16, 17,
2.5.34, 6, 7, 9, 15, 16, 17,
2.5.44, 5, 6, 7, 9, 15, 16,
17, 18, 19, 74, 2.5.54, 5, 6,
7, 9, 15, 16, 17, 18, 19
PCI−X Dell 2342M21, 38 FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150
03/04/2009 887 CLARiiON AX150