SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
568 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL 585 (G5), DL320 (G5), DL360 (G5),
DL385 (G5), DL585 (G5), ML350 (G5)40, ML370 (G5)40,
ML570 (G4)40;
IBM xSeries: x3550 (7978), x3650 (7979);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
Emulex LP1050−E1, 8, 9,
10 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
569 HPQ Proliant: DL365, DL385 (G2), DL585 (G2);
IBM xSeries x3755: (7163), (8877)
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
Emulex LP1050−E1, 8, 9,
10 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
570 Fujitsu Siemens Primergy BX620 S4;
HPQ Proliant: DL 585 (G5), DL320 (G5), DL360 (G5),
DL365, DL385 (G2), DL385 (G5), DL585 (G2), DL585
(G5), ML350 (G5)40, ML370 (G5)40, ML570 (G4)40;
Hewlett Packard Proliant ML350: (G4), (G4p)
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
Emulex LP1050−E8, 9, 10 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
571 Fujitsu Siemens Primergy RX220;
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7985),
x3755 (7163), x3755 (8877), x3800/x260 (8866),
x3850/x366 (8864)
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
Emulex LP1050Ex−E1, 8,
10, 55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
572 IBM xSeries x3655 (7943) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
Emulex LP1050Ex−E1, 8,
10, 55;
IBM: 39M5894
(QLA2460)1, 12, 13,
39M5895 (QLA2462)1, 12,
13, 42C2069
(LPe11000)1, 8, 10, 11,
42C2071 (LPe11002)1, 8,
10, 11;
QLogic:
QLA2460−E−SP1, 12, 13,
QLE2360−E−SP1, 12, 15,
28, QLE2460−E−SP1, 12,
13
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See44
573 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
IBM eServer 326m (Model 7969);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI��X
Emulex LP1050Ex−E1, 8,
10, 55;
QLogic
QLE2360−E−SP1, 12, 15,
28
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
574 HPQ Proliant: DL 585 (G5), DL385 (G5), DL585 (G5);
Hewlett Packard Proliant ML350: (G4), (G4p)
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
Emulex LP11000−E1, 8,
10, 11 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
575 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)40, ML370 (G5)40, ML570
(G4)40
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
Emulex LP11000−E1, 8,
10, 11 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
576 HPQ Proliant: DL 585 (G5), DL385 (G5), DL585 (G5) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
Emulex LP1150−E1, 8, 10,
11 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 843 CLARiiON AX150