VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
68 HPQ Proliant: DL380 (G4), DL580
(G3)33 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI,
PCI−X Emulex LP1050Ex−E2, 12, 23, 44 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
69 HPQ Proliant: DL380 (G4),
DL385, DL580 (G2)33, DL580
(G3)33, DL585, ML370 (G3)33,
ML370 (G4)33;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI,
PCI−X Emulex LP982−E2, 23, 34, 44 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
70 HPQ Proliant DL585 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI,
PCI−X HPQ AD167A/FC2143 (LP1150)1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
71 IBM: eServer 325 (Model 8835),
xSeries x445 (8870) VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI,
PCI−X IBM 24P0960 (QLA2340)21, 38, 63 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
72 Unisys ES7000/510 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Emulex LP9802DC−E2, 12, 23, 26, 31 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y83
73 Unisys: ES7000/520,
ES7000/530, ES7000/540 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Emulex LP9802DC−E2, 12, 23, 26, 31 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y83, 84
74 Unisys ES7000/510 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Emulex LP9802DC−E2, 23, 26, 31 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y84
75 Fujitsu Siemens Primergy BX620
S3 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Emulex LPe11002−E1, 2, 12, 26;
Fujitsu Siemens: BX600−FC22Q12, 29, 72,
BX600−FC42e12, 26, 88
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
76 Unisys: ES7000/510,
ES7000/520, ES7000/530,
ES7000/540
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Emulex: LP10000−E2, 23, 26, 31,
LP10000DC−E2, 23, 26, 31 FC−AL,
FC−SW EMC
CLARiiON
AX150
N See82
77 HPQ Proliant DL380 (G3) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Emulex: LP10000−E2, 23, 26, LP10000DC−E2,
23, 26, LP1050−E2, 23, 26, LP1050DC−E2, 23, 26,
LP8000−EMC26, 37, 42, LP9002−E
(LP9002L−E)2, 26, 37, LP9802−E2, 26, 35, 36,
LP9802DC−E2, 23, 26, 34, LP982−E2, 23, 26, 34;
HPQ: FCA2214/281541−B21 (QLA2340)29, 38,
FCA2214DC/321835−B21 (QLA2342)29, 38;
QLogic: QLA2200F−EMC29, 41,
QLA2310F−E−SP29, 38, 39, QLA2340−E−SP29,
38, 39, QLA2342−E−SP29, 38, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
78 Unisys: ES7000/510,
ES7000/520, ES7000/530,
ES7000/540
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Emulex: LP1050−E2, 23, 26, 31, LP1050DC−E2,
23, 26, 31, LP9002−E (LP9002L−E)2, 26, 31,
LP9802−E2, 26, 31, 35, 36
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y83, 84
79 Fujitsu Siemens Primergy: BX620
S273, BX630 (2−way), BX630
(4−way), BX66073
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Fujitsu Siemens BX600−FC22Q12, 29, 52, 72 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
80 HPQ Proliant: DL380 (G3), DL580
(G2)33 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI HPQ: AD167A/FC2143 (LP1150)1, 2, 12, 26,
AD168A/FC2243 (LP11002)1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
81 Unisys: ES7000/510,
ES7000/520, ES7000/530,
ES7000/540
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Unisys FCH752323−PCX (LP10000DC)2, 23, 26,
31 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
82 Unisys ES7000/510 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Unisys: FCH732213−P64 (LP9002L−F2)26, 31,
FCH742313−P64 (LP9802)26, 31 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
83 Unisys: ES7000/520,
ES7000/530, ES7000/540 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Unisys: FCH732213−P64 (LP9002L−F2)26, 31,
FCH742313−P64 (LP9802)26, 31 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y48
84 Unisys: ES7000/520,
ES7000/530, ES7000/540 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Unisys: FCH732213−P64 (LP9002L−F2)26, 31,
FCH742313−P64 (LP9802)26, 31,
FCH752313−PCX (LP1050)2, 23, 26, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
85 Unisys: ES7000/510,
ES7000/520, ES7000/530,
ES7000/540
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Unisys: FCH732213−P64 (LP9002L−F2)26, 31,
FCH742313−P64 (LP9802)26, 31,
FCH752313−PCX (LP1050)2, 23, 26, 31,
FCH752323−PCX (LP10000DC)2, 23, 26, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
86 Unisys: ES7000/510,
ES7000/520, ES7000/530,
ES7000/540
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI Unisys: FCH752313−PCX (LP1050)2, 23, 26, 31,
FCH752323−PCX31 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
87 IBM xSeries: x3350 (4192,4193),
x3455 (7940) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express Emulex LP10000ExDC−E2, 12, 23, 26;
QLogic: QLE2360−E−SP12, 29, 81,
QLE2362−E−SP12, 29, 81
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
88 Dell PowerEdge: 1950, 6850;
Fujitsu Siemens Primergy RX300
S3;
IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express Emulex LP1050Ex−E2, 12, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
89 Dell PowerEdge: 1850, 1950,
2800, 2850, 6800, 6850;
Fujitsu Siemens Primergy RX300:
S3, S4;
IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984),
x3850M2 (7233, 7234), x3950M2
(7233, 7234)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express Emulex LPe11000−E1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150
03/04/2009 864 CLARiiON AX150