Microsoft Windows 2008 [x64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
109 Dell PowerEdge 1950 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express Emulex: LP10000−E2, 4, 5,
18, 39, LP1050Ex−E2, 3, 4, 5,
18, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
110 Sun Sun Fire: X2200−M2, X4140, X4240, X4440 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express Emulex: LP11000−E1, 2, 3,
18, 21, LP11000−E1, 2, 3, 18,
21, 23, LP11002−E1, 2, 3, 18,
21, LP11002−E1, 2, 3, 18, 21,
23, LPe11000−E1, 2, 3, 18,
21, LPe11002−E1, 2, 3, 18,
21, LPe11002−E1, 2, 3, 18,
21, 23, LPe12000−E2, 3, 18,
21, 25, LPe12000−E2, 3, 18,
23, 25, LPe12002−E2, 3, 18,
21, 25, LPe12002−E2, 3, 18,
23, 25;
QLogic: QLE2460−E−SP3,
10, 12, 18, 51,
QLE2462−E−SP3, 10, 12, 18,
51, QLE2560−E−SP3, 10, 12,
18, QLE2562−E−SP3, 10, 12,
18;
Sun SG−XPCIE1FC−EM4:
(LPE11000)1, 2, 18, 21,
(LPE11000)1, 2, 18, 21, 23;
Sun
SG−XPCIE1FC−EM8−Z:
(LPe12000)2, 3, 18, 21, 25,
(LPe12000)2, 3, 18, 23, 25;
Sun: SG−XPCIE1FC−QF4
(QLE2460)10, 12, 18, 51,
SG−XPCIE1FC−QF8−Z
(QLE2560)3, 10, 12, 18,
SG−XPCIE2FC−EM4
(LPE11002)1, 2, 18, 21,
SG−XPCIE2FC−EM4
(LPE11002)1, 2, 18, 21, 23,
SG−XPCIE2FC−EM8−Z
(LPe12002)2, 3, 18, 21, 25,
SG−XPCIE2FC−EM8−Z
(LPe12002)2, 3, 18, 23, 25,
SG−XPCIE2FC−QF4
(QLE2462)10, 12, 18, 51,
SG−XPCIE2FC−QF8−Z
(QLE2562)3, 10, 12, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See47
111 IBM xSeries: x3850M2 (7233, 7234), x3950M2
(7233, 7234) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express Emulex: LPe11000−E1, 2, 3,
18, 21, 23, LPe11002−E1, 2,
3, 18, 21, 23, LPe12000−E2,
3, 18, 21, 23, 25,
LPe12002−E2, 3, 18, 21, 23,
25;
IBM: 39R6525 (QLE2460)3,
10, 12, 13, 18, 39R6527
(QLE2462)3, 10, 12, 13, 18,
42C2069 (LPe11000)1, 2, 3,
18, 21, 23, 42C2071
(LPe11002)1, 2, 3, 18, 21, 23,
42D0485 (LPe12000)2, 3,
21, 23, 25, 27, 42D0494
(LPe12002)2, 3, 21, 23, 25, 26,
42D0501 (QLE2560)3, 10,
12, 29, 42D0510
(QLE2562)3, 10, 12, 28;
QLogic: QLE2460−E−SP3,
12, 13, 18, QLE2460−E−SP3,
10, 12, 13, 18,
QLE2560−E−SP3, 10, 12, 18,
QLE2562−E−SP3, 10, 12, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9 See11
112 Sun Sun Fire: X4150, X4250, X4450 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI
Express Emulex: LPe11000−E1, 2, 3,
18, 21, 23, LPe11002−E1, 2,
3, 18, 21, 23, LPe12000−E2,
3, 18, 21, 23, 25,
LPe12002−E2, 3, 18, 21, 23,
25;
QLogic: QLE2460−E−SP3,
10, 12, 13, 18,
QLE2462−E−SP3, 10, 12, 13,
18, QLE2560−E−SP3, 10, 12,
18, QLE2562−E−SP3, 10, 12,
18;
Sun: SG−XPCIE1FC−EM4
(LPE11000)1, 2, 18, 21, 23,
SG−XPCIE1FC−EM8−Z
(LPe12000)2, 3, 18, 21, 23, 25,
SG−XPCIE1FC−QF4
(QLE2460)10, 12, 13, 18,
SG−XPCIE1FC−QF8−Z
(QLE2560)3, 10, 12, 18,
SG−XPCIE2FC−EM4
(LPE11002)1, 2, 18, 21, 23,
SG−XPCIE2FC−EM8−Z
(LPe12002)2, 3, 18, 21, 23, 25,
SG−XPCIE2FC−QF4
(QLE2462)10, 12, 13, 18,
SG−XPCIE2FC−QF8−Z
(QLE2562)3, 10, 12, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 216 CLARiiON AX150