SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
631 HPQ Proliant: DL380 (G5), DL580 (G4) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
Emulex LPe111−E1, 8, 10,
11 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
632 HPQ Proliant DL380 (G5) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
Emulex LPe12000−E1,
41, 54, 112 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See44
633 Fujitsu Siemens Primergy TX200 S4;
HPQ Proliant DL380 (G5) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
Emulex LPe12002−E1,
41, 112 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See44
634 Fujitsu Siemens Primergy TX200 S4 SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
Emulex LPe12002−E1,
10, 41, 112 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See44
635 Fujitsu Siemens Primergy TX200 S4 SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
Emulex LPe1250−E1, 10,
41, 112 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y58 See44
636 HPQ Proliant DL380 (G5) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
Emulex: LP101−E1, 8, 10,
55, LP1050−E8, 9, 10,
LP982−E8, 54, 55;
HPQ: AB429A/FC1143
(QLA2460)1, 12, 13,
AE369A/FC1243
(QLA2462)1, 12, 13
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
637 HPQ Proliant: DL380 (G5), DL580 (G4), DL580 (G5) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
Emulex: LP11000−E1, 8,
10, 11, LPe1150−E1, 8, 10,
11;
HPQ:
A8002A/FC2142SR
(LPe1150)1, 8, 10, 11,
AE311A/FC1142SR
(QLE2460)1, 12, 13,
AE312A/FC1242SR
(QLE2462)1, 12, 13
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
638 HPQ Proliant DL580 (G5) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
Emulex: LPe12000−E1,
41, 54, 112, LPe12002−E1,
41, 112
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y58 See22, 44
639 HPQ Proliant: DL380 (G4), DL580 (G3)40, DL580 (G4),
ML370 (G4)40 SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
Emulex: LPe12000−E1,
41, 54, 112, LPe12002−E1,
41, 112
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
640 Fujitsu Siemens Primergy TX200 S3 SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
QLogic
QLA2340−E−SP1, 12, 36 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
641 Fujitsu Siemens Primergy TX200 S3;
HPQ Proliant DL380 (G5) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
QLogic
QLA2340−E−SP12, 36 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
642 Fujitsu Siemens Primergy TX200 S3;
HPQ Proliant: DL380 (G5), DL580 (G4), DL580 (G5) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI, PCI
Express,
PCI−X
QLogic
QLE2460−E−SP1, 12, 13 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
643 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850;
HPQ Proliant: DL145, DL380 (G4), DL385, DL585, ML370
(G4)40;
Samsung: ES470, ES570, SS140
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI,
PCI−X Emulex LP101−E1, 8, 10,
55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
644 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850;
Fujitsu Siemens Primergy RX800 S2;
Samsung: ES470, ES570, SS140
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI,
PCI−X Emulex LP1050−E1, 8, 9,
10 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
645 HPQ Proliant DL585 SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI,
PCI−X Emulex LP1150−E1, 8, 10,
11 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
646 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850;
Samsung: ES470, ES570, SS140
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI,
PCI−X Emulex LP982−E1, 8, 54,
55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
647 HPQ Proliant: DL145, DL380 (G4), DL385, DL585, ML370
(G4)40 SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI,
PCI−X Emulex: LP1050−E8, 9,
10, LP11000−E1, 8, 10, 11,
LP982−E8, 54, 55
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
648 HPQ Proliant: DL140 (G3), DL145 (G2), DL380 (G4),
ML370 (G4)40 SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI,
PCI−X HPQ: AB429A/FC1143
(QLA2460)1, 12, 13,
AE369A/FC1243
(QLA2462)1, 12, 13
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
649 HPQ Proliant: DL140 (G3), DL145 (G2) SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI,
PCI−X HPQ:
AE311A/FC1142SR
(QLE2460)1, 12, 13,
AE312A/FC1242SR
(QLE2462)1, 12, 13;
QLogic:
QLA2460−E−SP1, 12, 13,
QLE2360−E−SP1, 12, 15,
28, QLE2460−E−SP1, 12,
13
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 850 CLARiiON AX150