Red Hat RHEL [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
180 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL585
(G2), ML350 (G5)63, ML370 (G5)63, ML570 (G4)63;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7985),
x3755 (8877), x3800/x260 (8866), x3850/x366 (8864)
Red Hat
RHEL
[x86_64]
4.0 U4
AS/ES9, 30
PCI
Express,
PCI−X
QLogic QLA2460−E−SP3,
20, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
181 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1850, 1900, 1950 III, 2850, 2900, 2900
III, 2950, 2950 III, 2970, 6800, 6850, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[x86_64]
4.0 U4
AS/ES9, 30
PCI
Express,
PCI−X
QLogic QLE220−E−SP3, 32,
33 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
182 Hewlett Packard Proliant ML350: (G4), (G4p) Red Hat
RHEL
[x86_64]
4.0 U4
AS/ES9, 30
PCI
Express,
PCI−X
QLogic QLE220−E−SP3, 32,
33, 47 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
183 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
IBM eServer 326m (Model 7969);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Red Hat
RHEL
[x86_64]
4.0 U4
AS/ES9, 30
PCI
Express,
PCI−X
QLogic QLE2360−E−SP2,
3, 34, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
184 IBM xSeries: x3800/x260 (8866), x3850/x366 (8864) Red Hat
RHEL
[x86_64]
4.0 U4
AS/ES9, 30
PCI
Express,
PCI−X
QLogic QLE2360−E−SP2,
34, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
185 IBM xSeries: x3655 (7985), x3800/x260 (8866),
x3850/x366 (8864) Red Hat
RHEL
[x86_64]
4.0 U4
AS/ES9, 30
PCI
Express,
PCI−X
QLogic QLE2360−E−SP3,
34, 39, 46 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
186 IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877) Red Hat
RHEL
[x86_64]
4.0 U4
AS/ES9, 30
PCI
Express,
PCI−X
QLogic QLE2360−E−SP3,
39, 46 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150