10. Driver Version SAN 4.4.9
11. Supports S10 Update 6 (10/08)
12. Supports S10 Update 5 (05/08)
13. Supports S10 Update 4 (08/07).
14. Fujitsu requires all patches for Solaris 10 be obtained through Fujitsu in the form of a Solaris 10 PTF patch CD. The current patch CD is Solaris 10 PTF R08081.
EMC requires Sun patches for Fujitsu PCI Bus servers running Solaris 10:
118833−36 SunOS 5.10: Kernel patch
120011−14 SunOS 5.10: Kernel patch
127111−11 SunOS 5.10: Kernel patch
137111−07 SunOS 5.10: Kernel patch
119130−33 SunOS 5.10: Sun Fibre Channel Device Drivers (only necessary for Leadville Stack driver)
125184−08 SunOS 5.10: Sun Fibre Channel Device Drivers
125166−12 SunOS 5.10: Qlogic ISP fibre channel device driver v2.29 (only required for Qlogic HBAs running Leadville)
120222−29 SunOS 5.10: Emulex−Sun LightPulse fibre channel adapter driver v2.31h (only required for Emulex HBAs running Leadville)
122640−05 SunOS 5.10: ZFS Genesis patch
15. To use PowerPath with GDS for the configuration (1) Solaris 10 Update 3, or (2) any Solaris 10 system with Sun patch 118833−36 or later, PowerPath 5.0.2 or later is required.
16. Only PrimePower servers with SPARC64−IV or SPARC64−V cpu's are supported with Solaris 10.
17. Driver Version 6.11cx2
18. Driver Version 6.11cx3
19. Driver Version SAN 4.4.12
20. For use in Asia Pacific/Japan only. Refer to Fujitsu Siemens Base Connectivity information for US/Europe.
21. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing required patch 120222−04. These packages are
available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
22. Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
23. FCode Value 1.50a8
24. Firmware Version 1.91a5
25. FCode Value 1.50a9
26. Driver Version SAN 4.4.14
27. Driver Version PFCA 3.0 Patch 120811−08
28. Use the Solaris 10 bundled driver PFCA 3.0 which requires patch 120811−05. PFCA Utility 3.0 and its patch 914180−04 need to be installed.
29. Driver Version PFCA 2.2.1
30. Driver Version PFCA 3.0 Patch 914180−07
31. Driver Version PFCA 2.2.1 Patch 912069−27
32. Fujitsu requires all patches for Solaris 8 be obtained through Fujitsu in the form of a Solaris 8 PTF patch CD. The current patch CD is Solaris 8 PTF R08081.
EMC requires Sun patches for Fujitsu PCI Bus servers running Solaris 8:
108528−29 SunOS 5.8: kernel update patch.
117000−05 SunOS 5.8: kernel patch
117350−47 SunOS 5.8: kernel patch
108974−56 SunOS 5.8: data, uata, dad, sd, and scsi patch.
109885−20 SunOS 5.8: glm patch
110918−06 SunOS 5.8: /kernel/drv/openeepr and prtconf patch
33. Driver Version PFCA 3.0
34. Driver Version PFCA 2.2.1 requires patch 912069−24.
35. Driver Version PFCA 3.0 requires patch 914180−04.
36. Fujitsu requires that all patches for Solaris 9 be obtained through Fujitsu in the form of a Solaris 9 PTF patch CD. The current patch CD is Solaris 9 PTF R08081.
EMC requires Sun patches for Fujitsu PCI Bus servers running Solaris 9:
112233−12 SunOS 5.9: kernel patch
117171−17 SunOS 5.9: kernel patch
118558−39 SunOS 5.9: kernel patch
122300−27 SunOS 5.9: Kernel Patch
112834−06 SunOS 5.9: patch SCSI
113277−61 SunOS 5.9: sd and ssd patch
Microsoft Windows 2000

Where replication of boot LUN is supported, any use of the replicated boot LUN other than in original host may lead to hardware/configuration

mismatch that render the replicated boot LUN unusable. Any issues that arise in trying to use the boot LUN in a host that is non−identical to the

source host is outside of the scope of what EMC can support. Also, in any case due to environment failure where I/O is not written back to the source

LUN, or if the source LUN is not left in a stable state by the source host, the replicated LUN is not guaranteed to be any more usable than the source.

Also, there may be specific software licensing that needs to be investigated when duplicating the boot LUN.

Microsoft Windows 2000
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
1 IBM Netfinity: 8500, 8500R;
IBM xSeries x37039
Microsoft
Windows
2000
Datacenter
SP481
PCI IBM 19K1246 (QLA2310)1, 8, 15, 19, 79,
80 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6
2 IBM xSeries x44039 Microsoft
Windows
2000
Datacenter
SP481
PCI−X IBM 19K1246 (QLA2310)1, 8, 15, 19, 79 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6
3 IBM xSeries x3800/x260 (8865)51 Microsoft
Windows
2000
Datacenter
SP481
PCI−X IBM 19K1246 (QLA2310)1, 8, 15, 19, 79,
80 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6
4 IBM xSeries x445 (8870) Microsoft
Windows
2000
Datacenter
SP481
PCI,
PCI−X IBM 19K1246 (QLA2310)1, 8, 15, 19, 79 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6
5 Dell PowerVault: 750N45, 755N36, 45, 770N45, 775N Microsoft
Windows
2000 Powered
Server
Appliance Kit
SP4 (SAK)
PCI Emulex LP1050−E8, 9, 10, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
N See13
6 Dell PowerVault: 750N, 755N36, 770N46, 775N Microsoft
Windows
2000 Powered
Server
Appliance Kit
SP4 (SAK)
PCI Emulex: LP101−E8, 9, 10, 11, 12,
LP982−E8, 10, 11, 12, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
N See13
CLARiiON AX150
03/04/2009 61 CLARiiON AX150