SuSE SLES [32−Bit]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
134 HPQ Proliant: BL260c G5 (quad core
processor)82, BL2x220c G5 (quad core
processor)82, BL460c (dual core
processor)82, BL460c (quad core
processor)82, BL465c (dual core
processor)82, BL465c G5 (quad core
processor)82, BL480c (dual core
processor)82, BL480c (quad core
processor)82, BL495c G5 (quad core
processor), BL680c (G5)82, BL685c (dual
core processor)82
SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express HPQ QLogic QMH2462 4Gb FC HBA for HP
c−Class Bladesystem (403619−B21)35, 83 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
135 IBM xSeries x3850M2: (7141)38, (7233,
7234);
IBM xSeries x3950M2: (7141)38, (7233, 7234)
SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express IBM: 42D0485 (LPe12000)11, 12, 13, 88, 89,
42D0494 (LPe12002)11, 12, 13, 40, 87 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y22, 74 See55
136 IBM xSeries: x3350 (4192,4193), x3455
(7940), x3455 (7984) SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express IBM: 42D0485 (LPe12000)11, 12, 13, 88, 89,
42D0494 (LPe12002)11, 12, 13, 40, 87 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y22
137 IBM xSeries x3455: (7940), (7984) SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express IBM: 42D0501 (QLE2560)2, 12, 35, 58, 42D0510
(QLE2562)2, 12, 35, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y22
138 IBM xSeries x3950M2 (7141)38 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express IBM: 42D0501 (QLE2560)2, 12, 35, 58, 42D0510
(QLE2562)2, 12, 35, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y22 See55
139 IBM xSeries: x3350 (4192,4193), x3850M2
(7141)38, x3850M2 (7233, 7234), x3950M2
(7233, 7234)
SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express IBM: 42D0501 (QLE2560)2, 12, 35, 58, 42D0510
(QLE2562)2, 12, 35, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y22, 74 See55
140 Dell PowerEdge: R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
IBM xSeries x3950M2 (7141)38
SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic QLE2460−E−SP2, 12, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See55
141 Digital Henge INNO FS7000;
HCL Infiniti Global Line 4700 FC;
HPQ Proliant DL785 (G5);
IBM xSeries x3850M2: (7141)38, (7233,
7234);
IBM xSeries x3950M2 (7233, 7234);
Intel S7000FC4UR;
LangChao NF520D2;
Lenovo SureServer R630 G7;
PowerLeader PR4850Q;
Samsung ZSS232;
Wipro NetPower Z4402
SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic QLE2460−E−SP2, 12, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y74 See55
142 Dell PowerEdge: R805, R900, R905;
Fujitsu Siemens Primergy RX300 S4;
IBM xSeries: x3350 (4192,4193), x3455
(7940), x3455 (7984), x3850M2 (7233, 7234),
x3950M2 (7233, 7234);
Sun Sun Fire: X2200−M2, X4140, X4150,
X4240, X4440, X4450
SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic QLE2460−E−SP2, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
143 HPQ Proliant DL785 (G5) SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic QLE2460−E−SP2, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See42
144 IBM xSeries: x3850M2 (7141)38, x3950M2
(7141)38 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic QLE2460−E−SP2, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31
145 Sun Sun Fire X4250 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic QLE2460−E−SP2, 35;
Sun: SG−XPCIE1FC−QF4 (QLE2460)35, 63,
SG−XPCIE2FC−QF4 (QLE2462)35, 63
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y31, 50,
51
146 Dell PowerEdge: R805, R900, R905;
HPQ Proliant DL785 (G5)
SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic QLE2462−E−SP2, 12, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See55
147 Dell PowerEdge: R805, R900, R905 SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic: QLE220−E−SP2, 12, 35, 49,
QLE2560−E−SP2, 12, 35, QLE2562−E−SP2, 12, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See55
148 IBM xSeries: x3350 (4192,4193), x3455
(7940), x3455 (7984) SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic: QLE220−E−SP2, 12, 35,
QLE2360−E−SP35, 64, 65 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
149 Dell PowerEdge: 1950, 1950 III, 2900 III,
2950 III, 2970, 6800, 6850, R805, R900,
R905;
IBM xSeries x3455 (7940)
SuSE
SLES
[32−Bit] 10
SP24, 5, 7,
8, 9, 33, 34
PCI
Express QLogic: QLE2560−E−SP2, 12, 35,
QLE2562−E−SP2, 12, 35 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 755 CLARiiON AX150