VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
121 Dell PowerEdge: 1950 III, 2900,
2900 III, 2950, 2950 III, 2970,
6950;
Fujitsu Siemens Primergy RX200:
S3, S4;
Fujitsu Siemens Primergy RX600:
S3, S4;
Fujitsu Siemens Primergy TX300:
S3, S4;
Fujitsu Siemens Primergy TX600
S3;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G4)33
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Emulex LPe1150−E1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
122 IBM xSeries x3755 (7163) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LP10000−E2, 23, 26, 31,
LP10000DC−E2, 23, 26, 31 FC−AL,
FC−SW EMC
CLARiiON
AX150
N See82
123 Dell PowerEdge: 1850, 1950 III,
2850, 2900, 2900 III, 2950, 2950
III, 2970, 6850, 6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2);
IBM xSeries: x336 (8837)71,
x3550 (7978), x3650 (7979),
x3755 (7163), x3755 (8877),
x3800/x260 (8866), x3850/x366
(8864);
NEC Express 5800 140He
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LP10000−E2, 23, 26, LP10000DC−E2,
23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
124 HPQ Proliant: DL385 (G2), DL585
(G2);
IBM xSeries x3755 (7163)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LP11000−E1, 2, 12, 26, 31, LP11002−E1,
2, 12, 26, 31 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
125 IBM xSeries: x3550 (7978), x3650
(7979), x3655 (7985), x3755
(8877), x3800/x260 (8866),
x3850/x366 (8864)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LP11000−E1, 2, 12, 26, LP11002−E1, 2,
12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
126 Dell PowerEdge: 1850, 1950 III,
2850, 2900, 2900 III, 2950, 2950
III, 2970, 6850, 6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2);
IBM xSeries: x336 (8837)71,
x3550 (7978), x3650 (7979),
x3800/x260 (8866), x3850/x366
(8864);
NEC Express 5800 140He
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Emulex: LP8000−EMC26, 37, 42, LP9002−E
(LP9002L−E)2, 26, 37, LP9802−E2, 26, 35, 36,
LP9802DC−E2, 23, 26, 34, LP982−E2, 23, 26, 34
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
127 Fujitsu Siemens Primergy BX620
S4 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Fujitsu Siemens: BX600−FC22Q12, 29, 72,
BX600−FC42e12, 26, 88 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
128 HPQ Proliant: DL360 (G5), DL585
(G2), ML370 (G5)33, ML570
(G4)33
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
HPQ: A8002A/FC2142SR (LPe1150)1, 2, 12, 26,
A8003A/FC2242SR (LPe11002)1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
129 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G4)33
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
HPQ: AB429A/FC1143 (QLA2460)12, 29, 32,
AE369A/FC1243 (QLA2462)12, 29, 32,
FCA2214/281541−B21 (QLA2340)29, 38,
FCA2214DC/321835−B21 (QLA2342)29, 38
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
130 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G4)33;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
HPQ: AD167A/FC2143 (LP1150)1, 2, 12, 26,
AD168A/FC2243 (LP11002)1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
131 HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), ML370 (G5)33,
ML570 (G3)33, ML570 (G4)33;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
HPQ: AE311A/FC1142SR (QLE2460)12, 29, 32,
AE312A/FC1242SR (QLE2462)12, 29, 32 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
132 IBM xSeries: x3550 (7978), x3650
(7979), x3800/x260 (8866),
x3850/x366 (8864)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
IBM 19K1246 (QLA2310)29, 38, 79 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
133 IBM xSeries: x3550 (7978), x3650
(7979), x3655 (7985), x3755
(7163), x3755 (8877), x3800/x260
(8866), x3850/x366 (8864)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
IBM: 24P0960 (QLA2340)29, 38, 63, 39M5894
(QLA2460)12, 29, 32, 39M5895 (QLA2462)12, 32,
80, 42D0405 (LP11000)1, 2, 12, 26, 42D0407
(LP11002)1, 2, 12, 26
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
134 IBM xSeries: x3550 (7978), x3650
(7979), x3655 (7943), x3655
(7985), x3755 (7163), x3755
(8877), x3800/x260 (8866),
x3850/x366 (8864)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
IBM: 39R6525 (QLE2460)12, 29, 32, 39R6527
(QLE2462)12, 29, 32, 42C2069 (LPe11000)1, 2,
12, 26, 42C2071 (LPe11002)1, 2, 12, 26
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
135 NEC Express 5800: 120Li, 120Lj,
120Rg−1, 120Rh−1, 120Ri−2,
120Rj−2, 140He
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
NEC N8190−120 (LP1050)2, 26, 35, 61 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150
03/04/2009 868 CLARiiON AX150