SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
206 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
Fujitsu Siemens Primergy: RX600 S3, TX600 S3;
HCL Infiniti Global Line 2700 AO;
IBM eServer 326m (Model 7969);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Emulex LP1050Ex−E1,
10, 34, 55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
207 IBM xSeries: x3655 (7985), x3755 (7163), x3755 (8877),
x3800/x260 (8866) SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Emulex LP1050Ex−E1,
10, 34, 55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
208 HPQ Proliant: DL 585 (G5), DL385 (G5), DL585 (G5);
Hewlett Packard Proliant ML350: (G4), (G4p)
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Emulex LP11000−E1, 10,
11, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
209 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)40, ML370 (G5)40, ML570
(G4)40;
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Emulex LP11000−E1, 10,
11, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14, 48,
49
210 HPQ Proliant: DL360 (G5), DL365;
IBM xSeries x3755: (7163), (8877)
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Emulex LP1150−E1, 10,
11, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
211 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Emulex LP982−E1, 34, 54,
55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
212 HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)40, ML370 (G5)40, ML570
(G4)40;
IBM xSeries: x3550 (7978), x3650 (7979), x3850/x366
(8864);
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Emulex LPe11000−E1,
10, 11, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14, 48,
49
213 Dell PowerEdge: 1900, 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950;
Fujitsu Siemens Primergy RX600 S4
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Emulex LPe11002−E1,
10, 11, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y43
214 Fujitsu Siemens Primergy BX620 S4;
HPQ Proliant: DL320 (G5), DL360 (G5), DL365, DL385
(G2), DL585 (G2), ML350 (G5)40, ML370 (G5)40, ML570
(G4)40;
IBM xSeries: x3550 (7978), x3650 (7979), x3850/x366
(8864);
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Emulex LPe11002−E1,
10, 11, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14, 48,
49
CLARiiON AX150
03/04/2009 800 CLARiiON AX150