Red Hat RHEL [32−Bit]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
100 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255065,
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 Red Hat
RHEL
[32−Bit]
4.0 U1
AS/ES4,
116, 117
PCI Emulex: LP1050−E3, 17, 49,
121, LP982−E3, 49, 57, 121;
QLogic QLA2340−E−SP3,
24, 120
FC−AL,
FC−SW EMC
CLARiiON
AX150
N118, 119
101 HPQ Proliant: DL320, DL360, DL360 (G2), DL380,
DL380 (G2), DL380 (G3), DL580 (G2)47, DL58047,
ML350 (G2)47, ML350 (G3)47, ML35047, ML370 (G2)47,
ML37047, ML530 (G2)47, ML530 (G3)47, ML53047,
ML57047, ML75047
Red Hat
RHEL
[32−Bit]
4.0 U1
AS/ES4,
116, 117
PCI QLogic QLA2340−E−SP20,
120 FC−AL,
FC−SW EMC
CLARiiON
AX150
N118, 119
102 Acer Altos: R710, R910;
Anders & Rodewyk Ariane: 145, 245, 420, 430, 620, 630;
Aquarius AquaServer: NQ312, TD322;
BGM Elitas: SP1010, SR1010, SR510, SR710;
Compusys ProManaged: SR1400JR2, SR2400JR2,
SR4850HW4, SR6850HW4;
Dell PowerEdge: 1800, 1850, 2800, 2850, 6800, 6850;
Digital Henge INNO: HR−4850, HR−4850T, HR−6850,
HR−6850T;
Digital Henge Revo: JS1400, JS2400;
Gateway: 9715, E−9415R, E−9515R;
HCL Infiniti Global Line 4700: HW, HW−2;
IBM xSeries x336 (8837)58;
Intel: SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
MPC NetFRAME: 1720, 2720, 6620;
MaxData Platinum: 1500 IR M5, 2200 IR M5, 7200 IR
M5, 7200 IR M6;
Nanobay: JR1400, JR2400, Nano E8501T, Nano
SR4850, Nano SR6850;
Ockam: ES OS−6400, OS−7000;
PowerLeader: PR1700, PR1700 G2, PR2700, PR2700
G2, PR4850, PR6850, PT6850;
R−Style MARSHALL: NP281r, NP282r, NP491;
Samsung: ZSS150, ZSS230−D, ZSS230−T;
Verari: RM2205, Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 6200, 6300, 6500, 8100, 8200
Red Hat
RHEL
[32−Bit]
4.0 U1
AS/ES4,
116, 117
PCI
Express Emulex LP1050Ex−E3, 17,
49, 121;
QLogic QLE2360−E−SP3,
25, 26, 120
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y118, 119
103 Dell PowerEdge 2850 Red Hat
RHEL
[32−Bit]
4.0 U1
AS/ES4,
116, 117
PCI
Express QLogic QLA200−E−SP3, 48,
69, 120 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y118, 119
104 Hewlett Packard Proliant ML350: (G4), (G4p) Red Hat
RHEL
[32−Bit]
4.0 U1
AS/ES4,
116, 117
PCI
Express,
PCI−X
Emulex: LP101−E3, 17, 49,
121, LP1050−E17, 49, 121,
LP982−E49, 57, 121;
QLogic: QLA200−E−SP3,
48, 120, QLA2340−E−SP20,
120
FC−AL,
FC−SW EMC
CLARiiON
AX150
N118, 119
105 Dell PowerEdge 1855 Red Hat
RHEL
[32−Bit]
4.0 U1
AS/ES4,
116, 117
PCI−X Dell 2342M20, 120 FC−AL,
FC−SW EMC
CLARiiON
AX150
N118, 119
CLARiiON AX150
03/04/2009 430 CLARiiON AX150