Microsoft Windows 2008 [x64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
269 HPQ Proliant: DL145 (G2), DL385, DL585 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex LP10000−E2, 4, 5,
18, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9, 59 See6
270 HPQ Proliant DL140 (G3) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex LPe1150−E1, 2, 3, 4,
5, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24, 59 See6
271 HPQ Proliant: DL580 (G3)31, DL585 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex: LP10000−E2, 3, 4,
5, 18, 39, LP10000DC−E2, 3,
4, 5, 18, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
272 HPQ Proliant DL145 (G2) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex: LP10000−E2, 3, 4,
5, 18, 39, LP10000DC−E2, 3,
4, 5, 18, 39, LPe1150−E1, 2,
3, 4, 5, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See6
273 Dell PowerEdge 1850 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex: LP10000−E2, 4, 5,
18, 39, LP10000DC−E2, 4, 5,
18, 39, LP9802−E4, 5, 18, 39,
49, LP9802DC−E4, 5, 18, 39,
49, LP982−E4, 5, 18, 39, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
274 Dell PowerEdge 1850;
HPQ Proliant: DL145 (G2), DL380 (G4), DL385,
DL580 (G3)31, DL585
Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex: LP1050−E2, 4, 5,
18, 39, LP1050DC−E2, 4, 5,
18, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
275 HPQ Proliant DL140 (G3) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex: LP11000−E1, 2, 3,
18, 21, 23, LP11002−E1, 2, 3,
18, 21, 23, LP1150−E1, 2, 3,
18, 21, 23
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9, 59 See6
276 HPQ Proliant: DL145 (G2), DL380 (G4), DL385,
DL580 (G3)31, DL585 Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex: LP11000−E1, 2, 3,
18, 21, 23, LP11002−E1, 2, 3,
18, 21, 23, LP1150−E1, 2, 3,
18, 21, 23
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
277 HPQ Proliant DL140 (G3) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex: LPe11000−E1, 2, 3,
4, 5, 18, LPe11002−E1, 2, 3,
4, 5, 14, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See6
278 HPQ Proliant DL145 (G2) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex: LPe12000−E2, 3, 4,
5, 25, LPe12002−E2, 3, 4, 5,
25;
HPQ: AJ762A (LPe12000)2,
3, 18, 21, 23, 25, AJ763A
(LPe12002)2, 3, 18, 21, 23, 25,
AJ764A (QLE2562)3, 10, 12,
18, AK344A (QLE2560)3, 10,
12, 18;
QLogic: QLE2460−E−SP3,
10, 12, 13, 18,
QLE2560−E−SP3, 10, 12,
QLE2562−E−SP3, 10, 12
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See11
279 HPQ Proliant DL140 (G3) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X Emulex: LPe12000−E2, 3, 4,
5, 25, LPe12002−E2, 3, 4, 5,
25;
HPQ: AJ762A (LPe12000)2,
3, 18, 21, 23, 25, AJ763A
(LPe12002)2, 3, 18, 21, 23, 25,
AJ764A (QLE2562)3, 10, 12,
18, AK344A (QLE2560)3, 10,
12, 18;
QLogic: QLE2560−E−SP3,
10, 12, QLE2562−E−SP3, 10,
12
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9, 24 See6, 11
280 HPQ Proliant: DL140 (G3), DL145 (G2) Microsoft
Windows
2008 [x64]:
Enterprise
Edition7,
Standard
Edition7
PCI,
PCI−X HPQ: A8002A/FC2142SR
(LPe1150)1, 2, 3, 18, 21, 23,
A8003A/FC2242SR
(LPe11002)1, 2, 3, 18, 21, 23,
AE311A/FC1142SR
(QLE2460)3, 10, 12, 13, 18,
AE312A/FC1242SR
(QLE2462)3, 10, 12, 13, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y24
CLARiiON AX150
03/04/2009 237 CLARiiON AX150