SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
611 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Digital Henge Revo: AS1500, AS1550, AS2500;
Fujitsu Siemens Primergy: BX620 S4, RX200 S3, RX600
S3, TX300 S3, TX600 S3;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL 585 (G5), DL385 (G5), DL585 (G5);
IBM eServer 326m (Model 7969);
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
QLogic
QLE2460−E−SP1, 12, 13 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
612 HPQ Proliant: DL365, DL385 (G2), DL585 (G2);
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7985),
x3755 (7163), x3755 (8877), x3800/x260 (8866),
x3850/x366 (8864)
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
QLogic
QLE2460−E−SP1, 12, 13 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
613 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
HPQ Proliant DL385 (G2)
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI
Express,
PCI−X
QLogic
QLE2460−E−SP1, 12, 13,
16
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
614 Dell PowerEdge 1855 SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI−X Dell LPe1105−M1, 8, 50,
64 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
615 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4, SR6850HW4;
Dell PowerEdge: 6800, 6850;
Digital Henge INNO: HR−4850, HR−4850T, HR−6850,
HR−6850T;
Digital Henge SH4500R4;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
Hewlett Packard Proliant DL360: (G4), (G4p);
IBM xSeries: x336 (8837)78, x346 (8840), x3800/x260
(8865)82, 83, x3850/x366 (8863)82, 83, x3950/x3950E/x460
(8872, 8874)82, 83;
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004, G5;
Lenovo SureServer: R650, R650 G5, T630 6003, T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: SS210, SS370, SS3840, ZSS230−D,
ZSS230−T;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI−X Emulex LP101−E1, 8, 10,
55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
616 Fujitsu Siemens Primergy RX200 S2;
IBM xSeries: x3800/x260 (8865)82, 83, x3850/x366
(8863)82, 83, x3950/x3950E/x460 (8872, 8874)82, 83
SuSE
SLES
[x86_64] 9
SP44, 5, 6, 7
PCI−X Emulex LP9802−E1, 8, 54,
55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 847 CLARiiON AX150