VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
31 Dell PowerEdge 1955 VMware ESX Server
3.04, 5, 6, 7, 8, 9, 10, 40 PCI, PCI
Express,
PCI−X
Dell 2342M21, 38 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
32 HPQ Proliant: DL380 (G5), DL580
(G4) VMware ESX Server
3.04, 5, 6, 7, 8, 9, 10, 40 PCI, PCI
Express,
PCI−X
Emulex LPe1150−E1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
33 HPQ Proliant DL380: (G3), (G4);
HPQ Proliant: DL385, DL580
(G2)33, DL580 (G3)33, ML370
(G3)33, ML370 (G4)33
VMware ESX Server
3.04, 5, 6, 7, 8, 9, 10, 40 PCI,
PCI−X HPQ AD167A/FC2143 (LP1150)1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
34 HPQ Proliant DL380 (G3) VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI Emulex: LP1050−E2, 23, 44, LP982−E2, 23, 34, 44;
QLogic QLA2340−E−SP21, 38, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
35 Fujitsu Siemens Primergy
BX66073 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI Fujitsu Siemens BX600−FC22Q12, 21, 52, 72 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
36 Dell PowerEdge: 1950, 6850;
Fujitsu Siemens Primergy RX300
S3
VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express Emulex LP1050Ex−E2, 12, 23, 44 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
37 Dell PowerEdge 1950 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express Emulex: LP1050−E2, 23, 44, LP982−E2, 23, 34, 44;
QLogic: QLA2340−E−SP21, 39, 52,
QLE2360−E−SP12, 21, 50
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
38 Fujitsu Siemens Primergy RX300
S3 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express QLogic QLA2340−E−SP21, 38, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
39 Dell PowerEdge 6850 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express QLogic QLE2360−E−SP12, 21 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
40 Dell PowerEdge 6850 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
Dell 2362M21, 66, 67 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
41 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850;
Fujitsu Siemens Primergy TX300
S3;
HPQ Proliant DL360 (G5);
IBM: eServer 326m (Model 7969),
xSeries x336 (8837)71
VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
Emulex LP1050Ex−E2, 12, 23, 44 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
42 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850;
HPQ Proliant DL360 (G5);
IBM xSeries: x336 (8837)71,
x3550 (7978), x3650 (7979);
NEC Express 5800 140He
VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
Emulex: LP1050−E2, 23, 44, LP982−E2, 23, 34, 44 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
43 HPQ Proliant DL360 (G5) VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
HPQ AB429A/FC1143 (QLA2460)12, 32, 43;
QLogic QLA2460−E−SP12, 32, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
44 HPQ Proliant: DL360 (G5),
ML370 (G5)33, ML570 (G3)33,
ML570 (G4)33;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
HPQ AE311A/FC1142SR (QLE2460)12, 32, 49 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
45 IBM xSeries: x3550 (7978), x3650
(7979) VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
IBM 24P0960 (QLA2340)21, 38, 63 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
46 NEC Express 5800: 120Li,
120Rg−1, 120Ri−2, 140He VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
NEC N8190−120 (LP1050)2, 35, 44, 61 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
47 Fujitsu Siemens Primergy TX300
S3;
HPQ Proliant DL360 (G5);
IBM xSeries: x336 (8837)71, x346
(8840), x3550 (7978), x3650
(7979)
VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
QLogic QLA2340−E−SP21, 38, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
48 Dell PowerEdge: 1850, 2850,
2900, 2950, 6850 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
QLogic QLA2340−E−SP21, 39, 52 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
49 Dell PowerEdge: 1850, 2850,
2900, 2950;
IBM eServer 326m (Model 7969)
VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
QLogic QLE2360−E−SP12, 21, 50 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
50 IBM eServer 326m (Model 7969) VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
QLogic QLE2460−E−SP12, 32, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
51 Dell PowerEdge: 2900, 2950 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
QLogic QLE2460−E−SP12, 32, 43, 59 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
52 Dell PowerEdge 1855 VMware ESX Server
3.05, 6, 7, 8, 9, 10, 40 PCI−X Dell 2342M21, 38 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150
03/04/2009 862 CLARiiON AX150