Microsoft Windows 2000
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
72 Acer Altos: R710, R720, R910;
Anders & Rodewyk Ariane: 145, 150, 155, 245, 250,
420, 430, 620, 630;
Aquarius AquaServer: NQ312, TD322;
BGM Elitas: SP1010, SR1010, SR510, SR520,
SR710, SR720;
Compusys ProManaged: SR1400JR2, SR1500PAL,
SR2400JR2, SR2500PAL, SR4850HW4,
SR6850HW4;
Digital Henge INNO: HR−4850, HR−4850T,
HR−6850, HR−6850T;
Digital Henge Revo: AS1500, AS1550, AS2500,
JS1400, JS2400;
Gateway: 9715, E−9415R, E−9515R;
HCL Infiniti Global Line: 2700 AO, 4700 HW, 4700
HW−2;
HPQ Proliant: DL360 (G5), DL380 (G4), DL380 (G5),
DL385 (G2), DL580 (G3)27, DL580 (G4), DL585 (G2),
ML350 (G5)27, ML370 (G4)27, ML370 (G5)27, ML570
(G4)27;
Hewlett Packard Proliant DL360: (G4)83, (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p);
Intel: SC5300AF2, SE7520BB2, SE7525RP2,
SR1400/SE7520JR2, SR1500/S5000PAL,
SR2400/SE7520JR2, SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
MPC NetFRAME: 1640, 1720, 1740, 2720, 2740,
6620;
MaxData Platinum 1500 IR: M5, M6;
MaxData Platinum 2200 IR: M5, M6;
MaxData Platinum 7200 IR: M5, M6;
Nanobay: JR1400, JR2400, Nano AL2500, Nano
E8501T, Nano SR4850, Nano SR6850;
Ockam: Duo OSPAL−4200R, ES OS−6400,
OS−7000;
PowerLeader: PR1700, PR1700 G2, PR2700,
PR2700 G2, PR4850, PR6850, PT6850;
R−Style MARSHALL: NP281r, NP282r, NP491;
Samsung: ZSS132, ZSS150, ZSS230−D, ZSS230−T;
Verari: RM2205, Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U, Z2105,
Z2205;
Wortmann TERRA AQUA: 6200, 6300, 6500, 8100,
8200;
Wortmann TERRA SERVER 6201
Microsoft
Windows
2000:
Advanced
Server SP414,
Server SP4
PCI
Express Emulex LPe1150−E3, 9, 10, 11, 17 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6, 7 See13
73 Dell PowerEdge: 1800, 1850, 1900, 1950, 2800,
2850, 2900, 2950, 6800, 6850, 6950 Microsoft
Windows
2000:
Advanced
Server SP414,
Server SP4
PCI
Express Emulex: LPe111−E3, 8, 9, 24, 25, 26,
LPe1150−E3, 9, 11, 25, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6, 7 See13
74 HPQ Proliant: DL360 (G5), DL380 (G4), DL380 (G5),
DL385 (G2), DL580 (G3)27, DL580 (G4), DL585 (G2),
ML350 (G5)27, ML370 (G4)27, ML370 (G5)27, ML570
(G4)27;
Hewlett Packard Proliant DL360: (G4)83, (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Microsoft
Windows
2000:
Advanced
Server SP414,
Server SP4
PCI
Express HPQ A8002A/FC2142SR (LPe1150)3,
9, 10, 11, 25 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6
75 HPQ Proliant DL380 (G4);
Hewlett Packard Proliant DL360: (G4)83, (G4p) Microsoft
Windows
2000:
Advanced
Server SP414,
Server SP4
PCI
Express HPQ AE311A/FC1142SR (QLE2460)1,
3, 8, 15, 16 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6
76 HPQ Proliant: DL360 (G5), DL380 (G5), DL385 (G2),
DL580 (G3)27, DL580 (G4), DL585 (G2), ML350
(G5)27, ML370 (G4)27, ML370 (G5)27, ML570 (G4)27;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Microsoft
Windows
2000:
Advanced
Server SP414,
Server SP4
PCI
Express HPQ AE311A/FC1142SR (QLE2460)1,
3, 8, 15, 16 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6, 28
CLARiiON AX150
03/04/2009 71 CLARiiON AX150