SuSE SLES [x86_64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
261 Dell PowerEdge: 1900, 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
QLogic:
QLE2560−E−SP1, 13, 29,
QLE2562−E−SP1, 13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
262 Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Sun:
SG−XPCI1FC−EM4−Z
(LP11000)1, 10, 11, 34,
SG−XPCI2FC−EM4−Z
(LP11002)1, 10, 11, 34,
SG−XPCIE1FC−EM4
(LPE11000)10, 11, 34,
SG−XPCIE2FC−EM4
(LPE11002)10, 34, 50, 51
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14, 48,
49
263 Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI
Express,
PCI−X
Sun: SG−XPCI1FC−QF4
(QLA2460)29, 65,
SG−XPCI2FC−QF4
(QLA2462)29, 65,
SG−XPCIE1FC−QF4
(QLE2460)29, 65,
SG−XPCIE2FC−QF4
(QLE2462)29, 65
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
264 Dell PowerEdge 1855 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Dell: 2342M29, 36,
LPe1105−M1, 34, 50, 64,
QME24621, 13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
265 Dell PowerEdge: 6800, 6850;
Hewlett Packard Proliant DL360: (G4), (G4p);
IBM xSeries: x336 (8837)78, x346 (8840), x3800/x260
(8865)82, 83, x3850/x366 (8863)82, 83, x3950/x3950E/x460
(8872, 8874)82, 83
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex LP101−E1, 10, 34,
55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
266 Fujitsu Siemens Primergy TX600 S2 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex LP1050−E1, 10,
34, 55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
267 Fujitsu Siemens Primergy TX600 S2 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex LP1050−E10, 34,
55, 59 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y48, 49
268 Fujitsu Siemens Primergy RX600 S2 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex LP1050Ex−E1,
10, 34, 55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
269 HPQ Proliant: DL140 (G3), DL145 (G2);
Hewlett Packard Proliant DL360: (G4), (G4p)
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex LP11000−E1, 10,
11, 34;
HPQ AB429A/FC1143
(QLA2460)1, 13, 29;
QLogic:
QLA2460−E−SP1, 13, 29,
QLA2462−E−SP1, 13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
270 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex LPe1150−E1, 10,
11, 34;
QLogic
QLE2460−E−SP13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y14
271 Dell PowerEdge: 6800, 6850;
IBM xSeries: x336 (8837)78, x346 (8840), x3800/x260
(8865)82, 83, x3850/x366 (8863)82, 83, x3950/x3950E/x460
(8872, 8874)82, 83
SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex: LP1050−E1, 10,
34, 55, LP982−E1, 34, 54,
55
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
272 Hewlett Packard Proliant DL360: (G4), (G4p) SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex: LP1050−E10, 34,
55, LP982−E34, 54, 55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
273 HPQ Proliant: DL140 (G3), DL145 (G2) SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex: LP1150−E1, 10,
11, 34, LPe11000−E1, 10,
11, 34, LPe11002−E1, 10,
11, 34, LPe1150−E1, 10,
11, 34;
HPQ A8002A/FC2142SR
(LPe1150)1, 10, 11, 34;
QLogic
QLE2460−E−SP13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
274 Dell PowerEdge: 1950, 6800, 6850 SuSE
SLES
[x86_64]
10 SP25, 6,
7, 20, 24, 30,
31
PCI−X Emulex: LPe12000−E1,
10, 34, 41, LPe12002−E1,
10, 34, 41;
QLogic:
QLA2340−E−SP29,
QLE2560−E−SP1, 13, 29,
QLE2562−E−SP1, 13, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 806 CLARiiON AX150