Microsoft Windows 2003 [x64]
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
90 IBM xSeries: x3650 (7979), x3755 (7163) Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
IBM: 42D0485
(LPe12000)19, 21, 22, 23,
36, 67, 42D0494
(LPe12002)19, 21, 22, 23,
36, 66
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 32 See1, 13
91 NEC Express 5800: 120Lj, 120Rh−1, 120Rj−2 Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI
Express,
PCI−X
NEC N8190−127
(LPe1150)8, 9, 10, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 14 See1, 13
92 Sun Sun Fire: X4100, X4200 Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X Emulex LP982−E4, 21,
22, 24 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3 See13
93 Dell PowerEdge: 1800, 2800, 2850, 6800, 6850;
IBM xSeries x3950/x3950E/x460 (8872, 8874)38;
Sun Sun Fire: V20z, V40z
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X Emulex LP982−E4, 21,
22, 24, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3 See13
94 Hewlett Packard Proliant DL360: (G4), (G4p) Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X HPQ AD167A/FC2143
(LP1150)19, 21, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y3
95 HPQ Proliant BL45p (G2) Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X HPQ Emulex−based
BL20p G3 Fibre
Channel Mezzanine
HBA − 394757−B214, 21,
22, 30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
96 HPQ Proliant BL45p Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X HPQ Emulex−based
BL25/30/35/45p Fibre
Channel Mezzanine
HBA − 394588−B214, 21,
22, 30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y3
97 IBM xSeries: x3650 (7979), x3655 (7985) Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X IBM: 42D0485
(LPe12000)19, 21, 22, 23,
36, 67, 42D0494
(LPe12002)19, 21, 22, 23,
36, 66
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3 See13
98 NEC Express 5800 180Re−3 Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X NEC N8190−120
(LP1050)4, 8, 9, 11, 30, 42 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y3
99 Sun Sun Fire: X4100, X4200 Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X Sun:
SG−XPCI1FC−EM4−Z
(LP11000)4, 19, 21, 22, 23,
26,
SG−XPCI2FC−EM4−Z
(LP11002)4, 19, 21, 22, 23,
26
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 32 See1, 13
100 HPQ Proliant BL20p: (G3), (G4);
HPQ Proliant BL25p (G2)
Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X16 HPQ Emulex−based
BL20p G3 Fibre
Channel Mezzanine
HBA − 394757−B214, 21,
22, 30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
101 HPQ Proliant BL25p Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI−X16 HPQ Emulex−based
BL25/30/35/45p Fibre
Channel Mezzanine
HBA − 394588−B214, 21,
22, 30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
102 HPQ Proliant: DL380 (G5), DL580 (G4) Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI, PCI
Express,
PCI−X
HPQ AD167A/FC2143
(LP1150)19, 21, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y3
103 HPQ Proliant DL140 (G3) Microsoft Windows 2003 [x64]
Enterprise Edition: R2 SP2,
SP2;
Microsoft Windows 2003 [x64]
Standard Edition: R2 SP2,
SP2
PCI,
PCI−X Emulex: LPe12000−E19,
21, 22, 23, 36,
LPe12002−E19, 21, 22,
23, 36;
HPQ: AJ762A
(LPe12000)4, 19, 21, 22,
23, 36, AJ763A
(LPe12002)4, 19, 21, 22,
23, 36
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 25,
32 See1
CLARiiON AX150
03/04/2009 87 CLARiiON AX150