Microsoft Windows 2000
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
38 Fujitsu Siemens Primergy: RX300 S2, TX300 S2 Microsoft
Windows
2000:
Advanced
Server SP4,
Server SP4
PCI−X Emulex LP1050Ex−E3, 8, 10, 11, 18, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y7See13
39 Dell PowerEdge: 2600, 2650, 2800, 2850, 4600,
6600, 6650, 6800, 6850;
Sun Sun Fire: X4100, X4200
Microsoft
Windows
2000:
Advanced
Server SP4,
Server SP4
PCI−X Emulex: LP101−E8, 9, 11, 12, 26,
LP982−E8, 11, 12, 18, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6, 7 See13
40 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4, SR6850HW4;
Dell PowerEdge: 1600SC, 1650, 1750;
Digital Henge INNO: HR−4850, HR−4850T,
HR−6850, HR−6850T, SH4500;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
HPQ Proliant: BL40p, DL360 (G3), DL560, DL740,
DL760, DL760 (G2), ML570 (G2)27;
IBM xSeries: x235, x255, x360, x365, x440;
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC2000, NC3000, NC3500, NF420,
NF500, NF520;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer R630 G5,
SureServer R650, SureServer R650 G5, SureServer
T630 6003, SureServer T630 6004, SureServer
T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: SS210, SS3400, SS3440, SS370,
SS3840, ZSS230−D, ZSS230−T;
Sun Sun Fire: V20z, V40z;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
Microsoft
Windows
2000:
Advanced
Server SP4,
Server SP4
PCI−X Emulex: LP101−E8, 9, 10, 11, 12,
LP982−E8, 10, 11, 12, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6, 7 See13
41 IBM xSeries: x3800/x260 (8865)51, x3850/x366
(8863)51, x3950/x3950E/x460 (8872, 8874)51 Microsoft
Windows
2000:
Advanced
Server SP4,
Server SP4
PCI−X Emulex: LP101−E8, 9, 10, 11, 12,
LP982−E8, 10, 11, 12, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6, 7, 28 See13
42 IBM xSeries x3950/x3950E/x460 (8872, 8874)51 Microsoft
Windows
2000:
Advanced
Server SP4,
Server SP4
PCI−X IBM 24P0960 (QLA2340)1, 8, 15, 19, 56 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
43 NEC Express 5800: 110Rg−1, 120Rf−1, 120Rh−2 Microsoft
Windows
2000:
Advanced
Server SP4,
Server SP4
PCI−X NEC N8190−120 (LP1050)8, 10, 11, 21,
53, 54 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
44 Dell PowerEdge: 1600SC, 1650, 1750;
Digital Henge INNO SH4500;
HPQ Proliant: BL40p, DL360 (G3), DL560, DL740,
DL760, DL760 (G2), ML570 (G2)27;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NF420;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440;
Sun Sun Fire: V20z, V40z
Microsoft
Windows
2000:
Advanced
Server SP4,
Server SP4
PCI−X QLogic QLA200−E−SP1, 2, 8, 15 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y6, 7 See4
CLARiiON AX150
03/04/2009 66 CLARiiON AX150