Oracle Enterprise Linux [x86_64]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
373 Sun Sun Fire: X4140, X4240, X4440 Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express QLogic: QLA2460−E−SP10, 21, 38,
QLA2462−E−SP10, 21, 38;
Sun SG−XPCI2FC−EM4−Z
(LP11002)7, 9, 10, 86
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
374 IBM xSeries: x3350 (4192,4193), x3455 (7940), x3455
(7984) Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express QLogic: QLE2360−E−SP10, 25, 38,
QLE2362−E−SP10, 25, 38 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
375 Sun Sun Fire: X2200−M2, X4140, X4150, X4240, X4250,
X4440, X4450 Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Sun: SG−XPCI1FC−EM4−Z
(LP11000)7, 8, 9, 10,
SG−XPCIE1FC−EM4 (LPE11000)7, 9,
10, 69, SG−XPCIE2FC−EM4
(LPE11002)7, 8, 10, 41, 42
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
376 Sun Sun Fire: X2200−M2, X4140, X4150, X4240 Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Sun: SG−XPCIE1FC−EM8−Z
(LPe12000)7, 8, 10, 57,
SG−XPCIE1FC−QF8−Z (QLE2560)10,
21, 38, SG−XPCIE2FC−EM8−Z
(LPe12002)7, 8, 10, 57,
SG−XPCIE2FC−QF8−Z (QLE2562)10,
21, 38
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14, 36
377 Sun Sun Blade Server Module: X6220, X6240, X6250,
X6450, X8440 Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express Sun: SG−XPCIE2FC−EB4−Z
(LPem11002)7, 8, 10, 42,
SG−XPCIE2FC−QB4−Z
(QEM2462)10, 21, 38
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
378 HPQ Proliant: DL 585 (G5), DL360 (G5), DL365, DL385
(G2), DL385 (G5), DL585 (G2), DL585 (G5), ML350
(G5)35, ML370 (G5)35, ML570 (G3)35, ML570 (G4)35
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express,
PCI−X
Emulex LP1050−E7, 8, 59, 67;
HPQ A8002A/FC2142SR (LPe1150)7,
8, 9, 10
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
379 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL 585 (G5), DL360 (G5), DL365, DL385
(G2), DL385 (G5), DL585 (G2), DL585 (G5), ML350
(G5)35, ML370 (G5)35, ML570 (G3)35, ML570 (G4)35;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express,
PCI−X
Emulex LP1050−E7, 8, 10, 59 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
380 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL, SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III,
2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL360 (G5), DL365, DL385 (G2), ML350
(G5)35, ML370 (G5)35, ML570 (G4)35;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express,
PCI−X
Emulex LP1050Ex−E7, 8, 10, 59 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
381 HPQ Proliant: DL 585 (G5), DL320 (G5), DL360 (G5),
DL365, DL385 (G2), DL385 (G5), DL585 (G2), DL585
(G5), ML350 (G5)35, ML370 (G5)35, ML570 (G3)35,
ML570 (G4)35;
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries: x3550 (7978), x3650 (7979), x3655 (7943),
x3655 (7985), x3755 (7163), x3755 (8877), x3800/x260
(8866), x3850/x366 (8864);
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2
Oracle
Enterprise
Linux
[x86_64]
5.311, 12,
13
PCI
Express,
PCI−X
Emulex LP11000−E7, 8, 9, 10 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 2, 3,
4, 5, 6 See14
CLARiiON AX150