Red Hat RHEL [32−Bit]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
1051 HPQ Proliant: DL140 (G3), DL145 (G2) Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI−X Emulex: LP1150−E3, 12, 16,
17, 18, LP1150−E3, 12, 17,
103, LPe11000−E3, 12, 16,
17, 18, LPe11000−E3, 12, 17,
103, LPe11002−E3, 12, 17,
LPe11002−E3, 12, 17, 103;
HPQ AB429A/FC1143:
(QLA2460)1, 3, 30, 31,
(QLA2460)1, 3, 31;
HPQ
FCA2214/281541−B21:
(QLA2340)20, 30, 31,
(QLA2340)20, 31;
HPQ
FCA2214DC/321835−B21:
(QLA2342)20, 30, 31,
(QLA2342)20, 31;
QLogic: QLA2460−E−SP3,
30, 31, 71, QLA2460−E−SP3,
31, 71, QLE2360−E−SP3, 25,
30, 31, QLE2360−E−SP3, 25,
31, QLE2362−E−SP3, 25, 30,
31, QLE2362−E−SP3, 25, 31,
QLE2462−E−SP3, 30, 31, 71,
QLE2462−E−SP3, 31, 71
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See27
1052 HPQ Proliant: DL140 (G3), DL145 (G2) Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI−X Emulex: LPe1150−E3, 12,
16, 17, 18, LPe1150−E3, 12,
17, 103
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
1053 Dell PowerEdge 1950 Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI−X Emulex: LPe12000−E3, 17,
45, 103, LPe12002−E3, 17,
45, 103;
QLogic: QLE2560−E−SP1,
3, 31, QLE2562−E−SP1, 3,
30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
1054 Dell PowerEdge: 6800, 6850 Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI−X Emulex: LPe12000−E3, 17,
45, 103, LPe12002−E3, 17,
45, 103;
QLogic: QLE2560−E−SP1,
3, 31, QLE2562−E−SP1, 3,
30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See27
1055 HPQ Proliant: DL140 (G3), DL145 (G2) Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI−X Emulex: LPe12000−E3, 17,
45, 103, LPe12002−E3, 45,
103, LPe1250−E3, 45, 103;
QLogic: QLE2560−E−SP1,
3, 30, 31, QLE2562−E−SP1,
3, 30, 31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See27, 28
1056 IBM xSeries x3950/x3950E/x460 (8878, 8879) Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI−X IBM 39M5894: (QLA2460)1,
3, 30, 31, (QLA2460)1, 3, 31;
IBM 39M5895: (QLA2462)1,
3, 30, 31, (QLA2462)1, 3, 31;
IBM 42D0405: (LP11000)3,
12, 16, 17, 18, (LP11000)3, 12,
17, 103;
IBM 42D0407: (LP11002)3,
12, 16, 17, 18, (LP11002)3, 12,
17, 103;
QLogic: QLA2460−E−SP3,
30, 31, 71, QLA2460−E−SP3,
31, 71
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32, 33 See27
1057 HPQ Proliant: DL140 (G3), DL145 (G2);
IBM xSeries x3950/x3950E/x460 (8878, 8879)
Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI−X QLogic: QLA2340−E−SP30,
31, 73, QLA2340−E−SP31,
73
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
1058 HPQ Proliant: DL140 (G3), DL145 (G2) Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI−X QLogic: QLE2360−E−SP30,
31, 122, QLE2360−E−SP31,
122
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See28
1059 HPQ Proliant: DL140 (G3), DL145 (G2) Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI−X QLogic: QLE2460−E−SP3,
30, 31, 71, QLE2460−E−SP3,
31, 71
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y32 See28
1060 Fujitsu Siemens Primergy TX200: S3, S4 Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI, PCI
Express,
PCI−X
Emulex LPe1150−E3, 12, 17,
103 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
1061 Fujitsu Siemens Primergy TX200 S4 Red Hat
RHEL
[32−Bit]
5.24, 8, 10,
11, 15
PCI, PCI
Express,
PCI−X
Emulex LPe1250−E3, 17, 45,
103 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y See28
CLARiiON AX150
03/04/2009 538 CLARiiON AX150