Asianux AX [32−Bit]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
198 Dell PowerEdge 1855 Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X Dell: 2342M21, 42, LPe1105−M9, 19, 26, 63,
QME24627, 9, 42 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
199 Dell PowerEdge: 2600, 2650, 6600, 6650 Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X Emulex LP101−E1, 6, 19;
QLogic QLA200−E−SP42, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
200 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950,
2600, 2650, 6600, 6650;
HPQ Proliant: DL360 (G3), DL560, DL740, DL760,
DL760 (G2), ML570 (G2)25;
Hewlett Packard Proliant DL360: (G4), (G4p)
Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X Emulex LP101−E1, 6, 9, 19;
QLogic QLA200−E−SP9, 42, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
201 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950,
2600, 2650, 6600, 6650;
Sun Sun Fire: V20z, V40z, X4100, X4200
Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X Emulex LP1050−E1, 6, 9, 19 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
202 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 2600,
2650, 6600, 6650;
Sun Sun Fire: V20z, V40z, X4100, X4200
Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X Emulex LP982−E9, 19, 28, 46 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
203 Dell PowerEdge: 2600, 2650, 6600, 6650;
HPQ Proliant: DL360 (G3), DL560, DL760, DL760
(G2), ML570 (G2)25;
Hewlett Packard Proliant DL360: (G4), (G4p)
Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X Emulex: LP1050−E1, 6, 19, LP982−E19, 28,
46 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
204 Hewlett Packard Proliant DL360: (G4), (G4p) Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X HPQ: AB429A/FC1143 (QLA2460)7, 9, 42,
AE369A/FC1243 (QLA2462)7, 9, 42;
QLogic QLA2462−E−SP7, 9, 42
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
205 NEC Express 5800: 120Lh, 120Re−1, 120Rf−1,
120Rg−2, 120Rh−2, 140He, 140Rd−4 Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X NEC N8190−120 (LP1050)1, 6, 19, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
206 NEC Express 5800: 140He, 140Rd−4 Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X NEC: N8190−127 (LPe1150)6, 14, 19, 38,
N8190−131 (LPe11002)6, 14, 19 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
207 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 2600,
2650, 6600, 6650;
HPQ Proliant: DL360 (G3), DL560, DL740, DL760,
DL760 (G2), ML570 (G2)25;
Hewlett Packard Proliant DL360: (G4), (G4p)
Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X QLogic QLA210−E−SP9, 42, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
208 Dell PowerEdge: 2600, 2650, 6600, 6650;
HPQ Proliant: DL360 (G3), DL560, DL740, DL760,
DL760 (G2), ML570 (G2)25;
Hewlett Packard Proliant DL360: (G4), (G4p)
Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X QLogic QLA2340−E−SP21, 42 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
209 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950;
Sun Sun Fire: V20z, V40z, X4100, X4200
Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X QLogic QLA2340−E−SP9, 21, 42 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
210 Hewlett Packard Proliant DL360: (G4), (G4p);
Sun Sun Fire: X4100, X4200
Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X QLogic QLA2460−E−SP7, 9, 42 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
211 HPQ Proliant: DL360 (G3), DL560, DL740, DL760,
ML570 (G2)25;
Hewlett Packard Proliant DL360: (G4), (G4p)
Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X QLogic QLE220−E−SP7, 9, 42 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
212 Sun Sun Fire: V20z, V40z, X4100, X4200 Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X Sun SG−XPCI1FC−QL2 (QLA2340)9, 42,
43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
213 Sun Sun Fire: X4100, X4200 Asianux
AX
[32−Bit]
3.03, 11, 20
PCI−X Sun: SG−XPCI1FC−EM4−Z (LP11000)6,
9, 14, 19, SG−XPCI1FC−QF4
(QLA2460)42, 50, SG−XPCI2FC−EM4−Z
(LP11002)6, 9, 14, 19, SG−XPCI2FC−QF4
(QLA2462)42, 50
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
214 Dell PowerEdge 1955 Asianux
AX
[32−Bit]
3.03, 11, 20
PCI, PCI
Express,
PCI−X
Dell: LPe1105−M9, 19, 26, 63, QME24627,
9, 42 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
215 HPQ Proliant: DL380 (G5), DL580 (G4) Asianux
AX
[32−Bit]
3.03, 11, 20
PCI, PCI
Express,
PCI−X
Emulex: LP101−E1, 6, 9, 19, LP1050−E1, 6,
19, LP982−E19, 28, 46, LPe111−E6, 9, 14,
19, LPe1150−E6, 9, 14, 19;
HPQ: A8002A/FC2142SR (LPe1150)6, 9,
14, 19, AE311A/FC1142SR (QLE2460)7, 9,
42, AE312A/FC1242SR (QLE2462)7, 9, 42;
QLogic: QLA200−E−SP9, 42, 45,
QLA210−E−SP9, 42, 45,
QLA2340−E−SP21, 42, QLE220−E−SP7, 9,
42, QLE2460−E−SP7, 9, 42
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 24 CLARiiON AX150