Asianux AX [32−Bit] 2.0

No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot
30 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255019, 4300,
4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450;
HPQ Proliant: DL320, DL360, DL360 (G2), DL380, DL380 (G2),
DL380 (G3), DL580 (G2)6, DL5806, ML350 (G2)6, ML350
(G3)6, ML3506, ML370 (G2)6, ML3706, ML530 (G2)6, ML530
(G3)6, ML5306, ML5706, ML7506
Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI QLogic: QLA200−E−SP1, 11, 12,
QLA210−E−SP1, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
31 HPQ Proliant: DL320, DL360, DL360 (G2), DL380, DL380 (G2),
DL380 (G3), DL580 (G2)6, DL5806, ML350 (G2)6, ML350
(G3)6, ML3506, ML370 (G2)6, ML3706, ML530 (G2)6, ML530
(G3)6, ML5306, ML5706, ML7506
Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI QLogic: QLA2340−E−SP11, 17,
QLE220−E−SP1, 11, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
32 Dell PowerEdge: 1800, 2800, 2850 Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express QLogic QLA2340−E−SP1, 11, 17 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
33 Dell PowerEdge 1950 Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express QLogic QLE220−E−SP1, 11, 22 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
34 Dell PowerEdge: 1800, 2800, 2850, 6800, 6850 Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express QLogic: QLA200−E−SP1, 11, 12,
QLA210−E−SP1, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
35 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850 Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express QLogic: QLE2360−E−SP1, 11, 20, 21,
QLE2460−E−SP1, 11, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
36 HPQ Proliant: DL320 (G5), DL360 (G5), DL385 (G2), DL585
(G2), ML350 (G5)6, ML370 (G5)6, ML570 (G4)6;
Hewlett Packard Proliant ML350: (G4), (G4p)
Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express,
PCI−X
HPQ AB429A/FC1143 (QLA2460)1, 11,
18;
QLogic QLA2462−E−SP1, 11, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
37 HPQ Proliant: DL320 (G5), DL360 (G5), DL385 (G2), DL585
(G2), ML350 (G5)6, ML370 (G5)6, ML570 (G4)6Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express,
PCI−X
HPQ: AE311A/FC1142SR (QLE2460)1,
11, 18, AE312A/FC1242SR
(QLE2462)1, 11, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
38 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III, 2970,
6800, 6850, 6950 Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express,
PCI−X
QLogic QLA2340−E−SP1, 11, 17 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
39 HPQ Proliant: DL320 (G5), DL360 (G5), DL385 (G2), DL585
(G2), ML350 (G5)6, ML370 (G5)6, ML570 (G4)6;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express,
PCI−X
QLogic QLA2460−E−SP1, 11, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
40 Dell PowerEdge: 1850, 1900, 1950 III, 2850, 2900, 2900 III,
2950, 2950 III, 2970, 6800, 6850, 6950 Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express,
PCI−X
QLogic QLE220−E−SP1, 11, 22 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
41 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III, 2970,
6800, 6850, 6950;
Hewlett Packard Proliant ML350: (G4), (G4p)
Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express,
PCI−X
QLogic: QLA200−E−SP1, 11, 12,
QLA210−E−SP1, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
42 Hewlett Packard Proliant ML350: (G4), (G4p) Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express,
PCI−X
QLogic: QLA2340−E−SP11, 17,
QLE220−E−SP1, 11, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
43 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950, 2950 III, 2970,
6950 Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI
Express,
PCI−X
QLogic: QLE2360−E−SP1, 11, 20, 21,
QLE2460−E−SP1, 11, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
44 Dell PowerEdge 1855 Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI−X Dell: 2342M11, 17, QME24621, 11, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
45 Hewlett Packard Proliant DL360: (G4), (G4p) Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI−X HPQ AB429A/FC1143 (QLA2460)1, 11,
18;
QLogic QLA2462−E−SP1, 11, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
46 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950, 2600,
2650, 6600, 6650;
HPQ Proliant: DL360 (G3), DL560, DL740, DL760, DL760 (G2),
ML570 (G2)6;
Hewlett Packard Proliant DL360: (G4), (G4p)
Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI−X QLogic QLA200−E−SP1, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
47 Dell PowerEdge: 2600, 2650, 6600, 6650 Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI−X QLogic QLA200−E−SP11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
48 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 2600, 2650,
6600, 6650;
HPQ Proliant: DL360 (G3), DL560, DL740, DL760, DL760 (G2),
ML570 (G2)6;
Hewlett Packard Proliant DL360: (G4), (G4p)
Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI−X QLogic QLA210−E−SP1, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
49 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950;
Sun Sun Fire: V20z, V40z, X4100, X4200
Asianux AX
[32−Bit] 2.0
SP313, 14, 15,
16
PCI−X QLogic QLA2340−E−SP1, 11, 17 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5
CLARiiON AX150
03/04/2009 29 CLARiiON AX150