VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
99 IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984),
x3850M2 (7141)105, x3850M2
(7233, 7234)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express IBM: 39R6525 (QLE2460)12, 29, 32, 39R6527
(QLE2462)12, 29, 32 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
100 IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984),
x3850M2 (7233, 7234), x3950M2
(7233, 7234)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express IBM: 42C2069 (LPe11000)1, 2, 12, 26, 42C2071
(LPe11002)1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
101 NEC Express 5800: 120Bb−6,
120Bb−d6, 120Bb−m6,
140Ba−10, B140a−T
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express NEC N8403−018 (LPe1105)12, 26, 45, 77 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
102 NEC Express 5800 140Rf−4 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express NEC: N8190−120 (LP1050)2, 26, 35, 61,
N8190−127 (LPe1150)2, 26, 45, 62 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
103 Fujitsu Siemens Primergy RX300
S3;
Sun Sun Blade Server Module:
X6240, X6440, X6450;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express QLogic QLA2340−E−SP29, 38, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
104 Dell PowerEdge: 1850, 1950,
1950 III, 2800, 2850, 2900 III,
2950 III, 2970, 6800, 6850, R805,
R900, R905;
Fujitsu Siemens Primergy RX300
S4;
HPQ Proliant DL785 (G5);
Sun Sun Blade Server Module:
X6240, X6440, X6450;
Sun Sun Fire: X2200−M2, X4140,
X4150, X4240, X4250, X4440,
X4450
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express QLogic QLE2560−E−SP12, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
105 Dell PowerEdge 1950;
IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express QLogic: QLE2360−E−SP12, 29, 50,
QLE2362−E−SP12, 29, 50 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
106 Dell PowerEdge: 1850, 1950,
1950 III, 2800, 2850, 2900 III,
2950 III, 2970, 6800, 6850, R805,
R900, R905;
HPQ Proliant DL785 (G5);
IBM xSeries: x3350 (4192,4193),
x3455 (7940)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express QLogic: QLE2460−E−SP12, 29, 32, 59,
QLE2462−E−SP12, 29, 59 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
107 Fujitsu Siemens Primergy RX300
S4;
HPQ Proliant DL785 (G5);
IBM xSeries: x3350 (4192,4193),
x3455 (7940), x3455 (7984),
x3850M2 (7141)105, x3850M2
(7233, 7234)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express QLogic: QLE2460−E−SP12, 29, 32,
QLE2462−E−SP12, 29, 32 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
108 Sun Sun Blade Server Module:
X6220, X6240, X6250, X6440,
X6450, X8440, X8450;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express Sun SG−XPCIE2FC−EB4−Z: (LPem11002)2, 12,
53, 54, (LPem11002)2, 12, 53, 55, 56 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y47 See46
109 Sun Sun Blade Server Module:
X6220, X6240, X6250, X6440,
X6450, X8440, X8450;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express Sun SG−XPCIE2FC−EB4−Z: (LPem11002)2, 12,
53, 57, (LPem11002)2, 12, 58 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
110 Sun Sun Blade Server Module:
X6220, X6240, X6250, X6440,
X6450, X8440;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express Sun SG−XPCIE2FC−QB4−Z: (QEM2462)12, 32,
92, (QEM2462)12, 59, 93 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y47 See46
111 Sun Sun Blade Server Module:
X6220, X6240, X6250, X6440,
X6450, X8440;
Sun Sun Fire: X4140, X4240,
X4440
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express Sun SG−XPCIE2FC−QB4−Z: (QEM2462)12, 59,
94, (QEM2462)12, 95, 96 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
112 IBM xSeries x3755: (7163),
(8877) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Emulex LP10000−E2, 12, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
113 Dell PowerEdge: 2850, 6850;
HPQ Proliant: DL385 (G2), DL585
(G2);
IBM xSeries: x3550 (7978), x3655
(7943), x3800/x260 (8866),
x3850/x366 (8864)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Emulex LP10000ExDC−E2, 12, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
114 HPQ Proliant: ML370 (G5)33,
ML570 (G4)33;
IBM xSeries x3755: (7163),
(8877)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI
Express,
PCI−X
Emulex LP1050−E2, 12, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150