VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
20 Dell PowerEdge: 1750, 2600,
2650, 6650;
Fujitsu Siemens Primergy:
RX300, RX300 S2, TX300,
TX300 S2;
HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)33, ML570 (G3)33;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365,
xSeries x3800/x260 (8865)65,
xSeries x3850/x366 (8863)65,
xSeries x3950/x3950E/x460
(8872, 8874)65, xSeries
x3950/x3950E/x460 (8878, 8879);
NEC Express 5800: 120Rh−2,
140Rd−4;
Sun Sun Fire: V40z, X4100,
X4200
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI−X Emulex LP1050−E2, 11, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
21 Fujitsu Siemens Primergy:
RX300, RX300 S2, RX600 S2,
TX300, TX300 S2, TX600 S2;
HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
(G2)33, ML570 (G3)33;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365,
xSeries x3800/x260 (8865)65,
xSeries x3850/x366 (8863)65,
xSeries x3950/x3950E/x460
(8872, 8874)65, xSeries
x3950/x3950E/x460 (8878, 8879);
Sun Sun Fire: V40z, X4100,
X4200
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI−X QLogic QLA2340−E−SP38, 39, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
22 HPQ Proliant: DL380 (G5), DL580
(G4) VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI, PCI
Express,
PCI−X
Emulex: LP1050−E2, 11, 23, LP982−E2, 11, 23, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
23 Fujitsu Siemens Primergy TX200
S3;
HPQ Proliant: DL380 (G5), DL580
(G4)
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI, PCI
Express,
PCI−X
Emulex: LP1050Ex−E2, 11, 12, 23, LPe1150−E1,
2, 11, 12;
QLogic QLA2340−E−SP38, 39, 43
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
24 HPQ Proliant DL380: (G4), (G5);
HPQ Proliant DL580: (G3)33,
(G4);
HPQ Proliant ML370 (G4)33
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI, PCI
Express,
PCI−X
QLogic QLE2460−E−SP12, 32, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
25 Fujitsu Siemens Primergy:
RX600, RX800 S2, RX800 S3,
TX600
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI,
PCI−X Emulex LP1050−E2, 11, 12, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
26 Fujitsu Siemens Primergy:
RX600, RX800 S2, RX800 S3,
TX600;
HPQ Proliant: DL380 (G4),
DL385, DL580 (G2)33, DL580
(G3)33, DL585, ML370 (G3)33,
ML370 (G4)33;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI,
PCI−X Emulex LP1050−E2, 11, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
27 Fujitsu Siemens Primergy:
RX600, RX800, RX800 S2,
RX800 S3, TX600;
HPQ Proliant: DL380 (G4),
DL385, DL580 (G2)33, DL580
(G3)33, DL585, ML370 (G3)33,
ML370 (G4)33;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
VMware ESX Server
3.0.13, 4, 5, 6, 7, 8, 9, 10 PCI,
PCI−X QLogic QLA2340−E−SP38, 39, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
28 Dell PowerEdge: 2900, 2950;
Fujitsu Siemens Primergy RX600
S3;
HPQ Proliant DL360 (G5)
VMware ESX Server
3.04, 5, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
Emulex LPe1150−E1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
29 HPQ Proliant DL360 (G5) VMware ESX Server
3.04, 5, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
HPQ A8002A/FC2142SR (LPe1150)1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
30 HPQ Proliant DL360 (G5);
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server
3.04, 5, 6, 7, 8, 9, 10, 40 PCI
Express,
PCI−X
HPQ AD167A/FC2143 (LP1150)1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150