Microsoft Windows 2003 [x64]
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
116 HPQ Proliant: DL 585 (G5), DL360 (G5), DL365,
DL385 (G2), DL385 (G5), DL580 (G5), DL585
(G2), DL585 (G5), ML350 (G5)28, ML370 (G5)28,
ML570 (G4)28
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
Emulex LP1050−E4, 22,
23, 24 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3 See13
117 Dell PowerEdge: 1900, 2900, 2950 Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
Emulex LP1050Ex−E4,
19, 22, 23, 24 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 25 See13
118 HPQ Proliant: DL 585 (G5), DL385 (G5), DL585
(G5);
IBM xSeries: x3655 (7943), x3755 (7163)
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
Emulex LP1150−E4, 19,
22, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3 See13
119 IBM xSeries: x3650 (7979), x3655 (7943), x3655
(7985) Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
Emulex LP982−E4, 22,
24, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 32 See13
120 IBM xSeries x346 (8840)53 Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
Emulex LPe111−E4, 19,
22, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 25 See13
121 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970;
HPQ Proliant: DL 585 (G5), DL365, DL385 (G2),
DL580 (G5), DL585 (G2), DL585 (G5);
IBM xSeries: x346 (8840)53, x3655 (7943), x3655
(7985)
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
Emulex LPe1150−E4, 19,
22, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 25 See13
122 HPQ Proliant DL385 (G5);
IBM xSeries x3755 (7163) Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
Emulex LPe1150−E4, 19,
22, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3 See13
123 HPQ Proliant: DL 585 (G5), DL365, DL385 (G2),
DL580 (G5), DL585 (G5) Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
HPQ
A8002A/FC2142SR
(LPe1150)19, 22, 23, 26
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y3, 25
124 HPQ Proliant: DL 585 (G5), DL360 (G5), DL365,
DL385 (G2), DL385 (G5), DL580 (G5), DL585
(G2), DL585 (G5), ML350 (G5)28, ML370 (G5)28,
ML570 (G4)28
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
HPQ AD167A/FC2143
(LP1150)19, 22, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y3
125 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970;
IBM xSeries x3655 (7943)
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI
Express,
PCI−X
QLogic
QLE2360−E−SP4, 6, 7,
17
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 25 See1
126 Dell PowerEdge: 1800, 2800, 2850, 6800, 6850;
HPQ Proliant ML570 (G3)28;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries x3950/x3950E/x460 (8872, 8874)38;
Sun Sun Fire: V20z, V40z, X4100, X4200
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI−X Emulex LP1050−E4, 22,
23, 24 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3 See13
127 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4,
SR6850HW4;
Digital Henge INNO: HR−4850, HR−4850T,
HR−6850, HR−6850T;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R630 G5, R650, R650 G5,
T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: ZSS230−D, ZSS230−T;
Sun Sun Fire: X4100, X4200;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI−X Emulex LP1150−E4, 19,
22, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3, 32 See13
128 HPQ Proliant: DL360 (G5), DL365, DL380 (G5),
DL385 (G2), DL585 (G2), ML570 (G3)28;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries: x3650 (7979), x3655 (7985),
x3950/x3950E/x460 (8878, 8879);
Sun Sun Fire: V20z, V40z
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2 PCI−X Emulex LP1150−E4, 19,
22, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y2, 3 See13
CLARiiON AX150
03/04/2009 90 CLARiiON AX150