Microsoft Windows 2008 [x64]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
12 HPQ Proliant: DL360 (G5), DL380 (G4), DL385
(G2), DL580 (G4), DL585 (G2), ML570 (G4)31 Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express HPQ: A8002A/FC2142SR
(LPe1150)1, 2, 3, 18, 21, 23,
A8003A/FC2242SR
(LPe11002)1, 2, 3, 18, 21, 23,
AE311A/FC1142SR
(QLE2460)3, 10, 12, 13, 18,
AE312A/FC1242SR
(QLE2462)3, 10, 12, 13, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y24
13 HPQ Proliant: DL380 (G4), DL580 (G4), DL785
(G5) Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express HPQ: AJ762A (LPe12000)2,
3, 18, 21, 23, 25, AJ763A
(LPe12002)2, 3, 18, 21, 23, 25,
AJ764A (QLE2562)3, 10, 12,
18, AK344A (QLE2560)3, 10,
12, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See6, 11
14 Dell PowerEdge: R805, R900, R905 Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express QLogic QLE220−E−SP3, 10,
12, 13, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See11
15 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970 Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express QLogic QLE2460−E−SP3,
10, 12, 13, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See11
16 Dell PowerEdge: R805, R900, R905;
HPQ Proliant: DL360 (G5), DL380 (G4), DL385
(G2), DL580 (G4), DL585 (G2), ML570 (G4)31
Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express QLogic QLE2460−E−SP3,
10, 12, 13, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See11
17 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970,
R805, R900, R905 Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express QLogic QLE2462−E−SP3,
10, 12, 13, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9 See11
18 HPQ Proliant: DL360 (G5), DL380 (G4), DL385
(G2), DL580 (G4), DL585 (G2), ML570 (G4)31 Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express QLogic QLE2462−E−SP3,
10, 12, 13, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See11
19 HPQ Proliant: DL360 (G5), DL385 (G2), DL585
(G2) Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex LP10000−E2, 4, 5,
18, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 9, 59 See6
20 HPQ Proliant: DL360 (G5), DL385 (G2), DL585
(G2), DL585 (G5), ML570 (G4)31 Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex LP1050−E2, 4, 5, 18,
39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
21 HPQ Proliant: DL360 (G5), DL385 (G2), DL585
(G2), ML570 (G4)31 Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex LP1050DC−E2, 4, 5,
18, 39 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
22 HPQ Proliant DL585 (G5) Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex LP1150−E1, 2, 3, 18,
21, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
23 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970 Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex LPe1150−E1, 2, 3, 4,
5, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
24 HPQ Proliant: DL385 (G2), DL585 (G2), DL585
(G5) Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex LPe1150−E1, 2, 3, 4,
5, 18 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See6
25 HPQ Proliant DL360 (G5) Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex: LP10000−E2, 3, 4,
5, 18, 39, LP10000DC−E2, 3,
4, 5, 18, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24, 59 See6
26 HPQ Proliant: DL585 (G2), ML570 (G4)31 Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex: LP10000−E2, 3, 4,
5, 18, 39, LP10000DC−E2, 3,
4, 5, 18, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
27 HPQ Proliant DL360 (G5) Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex: LP11000−E1, 2, 3,
18, 21, 23, LP11002−E1, 2, 3,
18, 21, 23
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8See6
28 HPQ Proliant: DL360 (G5), DL385 (G2), DL585
(G2) Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex: LPe11000−E1, 2, 3,
4, 5, 18, LPe11002−E1, 2, 3,
4, 5, 14, 18
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See6
29 HPQ Proliant DL385 (G2) Microsoft
Windows
2008 [x64]
DataCenter7
PCI
Express,
PCI−X
Emulex: LPe12000−E2, 3, 4,
5, 25, LPe12002−E2, 3, 4, 5,
25;
HPQ: AJ762A (LPe12000)2,
3, 18, 21, 23, 25, AJ763A
(LPe12002)2, 3, 18, 21, 23, 25,
AJ764A (QLE2562)3, 10, 12,
18, AK344A (QLE2560)3, 10,
12, 18;
QLogic: QLE2560−E−SP3,
10, 12, QLE2562−E−SP3, 10,
12
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y8, 24 See6, 11
CLARiiON AX150
03/04/2009 209 CLARiiON AX150