103. FSC Fibre Channel module. Dual channel 4GBit/s HBA for BX6xx−series blade servers only.
104. BIOS 3.02a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
105. Internal port(s) on Qlogic or McData 4Gb FC switch module(s) must be set to 4Gb (if 4Gb operation is required or to 2Gb if 2Gb operation is required)
106. BIOS 2.01 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
107. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
108. BIOS 2.02a1
109. Driver Version 8.01.00
110. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
111. BIOS 4.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com EFI Boot code. Boot support for 64−Bit servers can be accomplished in two
ways depending on your server. If your server does not have support for Legacy Option ROMs that use INT 13 for external boot, then an EFI boot driver must be used instead. Refer
to your server documentation as to whether your server supports Legacy Option ROM loading.
112. Driver Version 8.0.16.40 Driver is in the kernel 2.6.5−7.311 and available from both Novell and Emulex as a driver update for kernel 2.6.5−7.308. Driver is integrated into the kernel.
113. Requires IBM Multi−Switch Interconnect Module for IBM BladeCenter (39Y9314) installed in IBM BladeCenter H and with appropriate fibre channel switch modules to installed in
bays 8 & 10.
114. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
115. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
116. Driver Version 8.1.10.3 Driver is integrated into the kernel. DS−M Connect ONLY interoperates with ControlCenter Host Agent, Symmetrix SDM Agent, Storage Agent for Symmetrix.
117. BIOS 2.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
118. Driver Version 8.2.0.22 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
119. Driver Version 8.01.02−sles Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
120. Driver Version 8.1.10.9
121. Driver Version 8.1.10.3
122. Driver Version 8.0.16.27
Sun Solaris
Sun Solaris
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
1 Sun Netra T20001Sun Solaris 10
S10 Update 1
(01/06)8, 9, 11, 12,
14, 15, 49
PCI−X QLogic
QLA2460−E−SP2, 5,
6, 7, 20, 43, 44, 45, 46
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y40
2 Sun Sun Fire: V2151, V245, V445 Sun Solaris 10
S10 Update 2
(06/06)8, 9, 10, 11,
12, 14, 15, 16, 19, 49
PCI
Express,
PCI−X
QLogic
QLA2460−E−SP2, 5,
6, 7, 20, 43, 44, 45, 46
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y40
3 Sun Sun Fire: V2151, V245, V445 Sun Solaris 10
S10 Update 2
(06/06)8, 9, 10, 11,
12, 14, 15, 16, 19, 49
PCI
Express,
PCI−X
QLogic
QLE2460−E−SP2, 5,
6, 7, 20, 46
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
4 Sun Sun: Fire T20001, SPARC Enterprise T20001Sun Solaris 10
S10 Update 3
(11/06)8, 9, 10, 11,
12, 14, 15, 19
PCI−X QLogic
QLA2460−E−SP2, 5,
6, 7, 20, 43, 44, 45, 46
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y40
5 Sun Sun SPARC Enterprise: M40001, 53, M5000 Sun Solaris 10
S10 Update 3
(11/06)8, 9, 10, 11,
12, 14, 15, 49
PCI−X QLogic
QLA2460−E−SP2, 5,
6, 7, 20, 43, 44, 45, 46
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y40
6 Sun: Netra 12901, Sun Fire 280R, Sun Fire 29001, Sun Fire
48001, Sun Fire 4810, Sun Fire 6800, Sun Fire 69001, Sun Fire
E4900
Sun Solaris 108, 9,
10, 11, 12, 13, 14, 15,
16, 17, 18, 19
PCI QLogic
QLA2340−E−SP2, 3,
4, 5, 6, 7, 20, 21, 22, 23,
24, 25
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
7 Sun Netra: 1201, 12801, 12901, 14001, 14051, N2401, N4401;
Sun Sun Blade: 10001, 15001, 1501, 20001, 25001;
Sun Sun Fire: 12K1, 15K, 20k, 25k, 280R, 29001, 48001, 4810,
6800, 69001, E4900
Sun Solaris 108, 9,
10, 11, 12, 13, 14, 15,
16, 17, 18, 19
PCI QLogic
QLA2460−E−SP2, 5,
6, 7, 20, 43, 44, 45, 46
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y40 See41, 42
8 Sun Sun Fire: V1001, V120, V12801, V2101, V2401, V2501,
V440, V4801, V4901, V880, V890 Sun Solaris 108, 9,
10, 11, 12, 14, 15, 16,
17, 18, 19
PCI QLogic
QLA2340−E−SP2, 3,
4, 5, 6, 7, 20, 21, 22, 23,
24, 25
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
9 Sun Sun Fire: V1001, V120, V12801, V2101, V2401, V2501,
V440, V4801, V4901, V880, V890 Sun Solaris 108, 9,
10, 11, 12, 14, 15, 16,
17, 18, 19
PCI QLogic
QLA2460−E−SP2, 5,
6, 7, 20, 43, 44, 45, 46
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y40 See41, 42
10 Sun Sun Fire: 280R, 29001, 48001, 4810, 6800, 69001, E4900 Sun Solaris 109,
10, 11, 12, 13, 14, 15,
16, 17, 18, 19
PCI Sun X6767A
(SG−XPCI1FC−QF2)2,
6, 7, 20, 25, 32, 33
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
11 Sun Sun Fire: V1001, V120, V12801, V2101, V2401, V2501,
V440, V4801, V4901, V880, V890 Sun Solaris 109,
10, 11, 12, 14, 15, 16,
17, 18, 19
PCI Sun X6767A
(SG−XPCI1FC−QF2)2,
6, 7, 20, 25, 32, 33
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
12 Sun Sun Fire: 12K1, 15K, 20k, 25k, 29001, 69001, E4900 Sun Solaris 8
02/0415, 50, 51 PCI QLogic
QLA2460−E−SP20,
25, 26, 30, 34, 36, 37, 43,
44, 45, 46, 47
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y40 See41, 42
13 Sun Netra: N2401, N4401;
Sun Sun Fire: V2401, V2501, V440
Sun Solaris 8
07/0315, 50, 51 PCI QLogic
QLA2460−E−SP20,
25, 26, 30, 34, 36, 37, 43,
44, 45, 46, 47
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y40 See41, 42
14 Sun Sun Fire: 280R, 29001, 48001, 4810, 6800, 69001, E4900,
V1001, V120, V12801, V2101, V2401, V2501, V440, V4801,
V4901, V880, V890
Sun Solaris 815 PCI QLogic
QLA2340−E−SP3, 4,
21, 22, 23, 24, 26, 27, 28,
30, 38, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
15 Sun Sun Blade: 10001, 15001, 20001, 25001;
Sun Sun Fire: 280R, 29001, 48001, 4810, 6800, 69001, E4900,
V1001, V120, V12801, V2101, V2401, V2501, V440, V4801,
V4901, V880, V890
Sun Solaris 815 PCI Sun X6767A
(SG−XPCI1FC−QF2)20,
25, 30, 32, 33, 34, 36, 37
FC−AL,
FC−SW EMC
CLARiiON
AX150
N
16 Sun Netra: 1201, 12801, 14001, 14051, 20;
Sun Sun Blade: 10001, 15001, 1501, 20001, 25001;
Sun Sun Fire: 12K1, 15K, 20k, 25k, 280R, 48001, 4810, 6800,
V1001, V120, V12801, V2101, V2401, V440, V4801, V4901,
V880, V890
Sun Solaris 815,
50, 51 PCI QLogic
QLA2460−E−SP20,
25, 26, 30, 34, 36, 37, 43,
44, 45, 46, 47
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y40 See41, 42
CLARiiON AX150
03/04/2009 856 CLARiiON AX150